Description
Series: CX-1085M
Type: Pneumatic Time Delays
Pneumatic timer for push buttons
Brand: Camden
Manufacturer Part Number: CX-1085M
Source: Camden Controls product page
Series: CX-1085M
Type: Pneumatic Time Delays
Pneumatic timer for push buttons
Brand: Camden
Manufacturer Part Number: CX-1085M
Source: Camden Controls product page
Camden Door Controls CX-1085M pneumatic time delay requires no power to operate. The timing range is 1 – 60 seconds, and is easily adjusted by a thumbscrew. Camden CX-1085M Pneumatic Timer is integrated into the CM-4085/4185, 5085, 7085/7185 and CM-8085/8185 Push Buttons.
| Low-voltage wiring | Required |
|---|---|
| Basis | Structured, independently qualified product connection evidence |
| Preparation | Fit the CX-1085M to the compatible purchased pushbutton assembly; the manufacturer lists CM-4085, CM-4185, CM-5085, CM-7085, CM-7185, CM-8085 and CM-8185. The side view shows the retaining nut/washer and timing screw with a pushbutton, which is sold separately when ordering the standalone timer. Confirm the actual assembly clearance before installation: the dimension table and drawing differ, so they are not an unambiguous standalone cutout template. Adjust the pneumatic delay with the thumbscrew and verify the required operating time after assembly. |
| Electrical | The pneumatic timing mechanism requires no operating power supply. Its DPST Form Z switch contacts still require connection to the selected external control circuit. The drawing identifies four factory lead ends, two blue and two orange, but does not map these colors to the NO/NC contact functions; verify the actual contact pairs and state before wiring. Do not substitute the red/white lead mapping from another complete pushbutton assembly. The factory lead count does not establish field conductor count, physical cable runs, cable type, gauge or shielding. Select those from the actual controlled circuit and installation layout. |
| Electrical wiring required | Yes |
| Conditional connections | CX-1085M factory contact lead ends: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating Four factory tails, two blue and two orange; contact pair/function mapping unprovided.; endpoints CX-1085M internal switch contacts to Two blue and two orange factory lead ends; when Installation configuration is Internal accessory connection; not field cable: Factory timer tails for the selected low-voltage controlled circuit; confirm NO/NC pairing before extending or connecting. These are distinct from field cable jackets and physical runs.; CX-1085M selected external contact circuit: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating Field cable schedule depends on verified contact-pair use and connected equipment; type/gauge/shielding undocumented.; endpoints Verified CX-1085M contact pairs to Selected low-voltage controlled equipment; when Installation configuration is After verifying the actual lead-to-contact mapping and choosing the used contact functions; factory four-wire count does not specify a field cable bundle. |