CM-120I – CM-120: Flush Mount Wired and Wireless Keypads

Price range: $14.99 through $189.99

CM-120: Flush Mount Wired and Wireless Keypads – Camden Door Controls

SKU: CM-120i
Category: ,
Brands:

Description

CM-120: Flush Mount Wired and Wireless Keypads – Camden Door Controls

Source: https://www.camdencontrols.com/products/CM_120i

Resources:
https://www.camdencontrols.com/pipelines/resource/5972_CM_120TX_Spec_Sheet_R3.pdf
https://www.camdencontrols.com/pipelines/resource/5973_803OPGJKZC6EELT39DB9.pdf
https://www.camdencontrols.com/pipelines/resource/5974_CM_120_Spec_Sheet_R2.pdf
https://www.camdencontrols.com/pipelines/resource/5975_U6VO3NKKH7FU8K15E946.pdf
https://www.camdencontrols.com/pipelines/resource/5976_CM_120_V3_Series_Keypads_Manual_R7.pdf
https://www.camdencontrols.com/pipelines/resource/5977_WQM6A9EE2C34F05633WL.pdf
https://www.camdencontrols.com/pipelines/resource/5978_CM_120_V3_Series_Keypads_Manual_R7_FR.pdf
https://www.camdencontrols.com/pipelines/resource/5979_XTNFQ3XLRDG4SHVNWE19.pdf
https://www.camdencontrols.com/pipelines/resource/5980_CM_120_Series_Keypads_Programming_Guide_R3.pdf
https://www.camdencontrols.com/pipelines/resource/5981_1ENKEYETFJFF3EGDHQWV.pdf
https://www.camdencontrols.com/pipelines/resource/5982_CM_120_Series_Keypads_Programming_Guide_French_R3.pdf
https://www.camdencontrols.com/pipelines/resource/5983_9X24QP2X76LOQTW8P25C.pdf
https://www.camdencontrols.com/pipelines/resource/5984_CM_120TX_Manual_R1.pdf
https://www.camdencontrols.com/pipelines/resource/5985_UGPCMO9OGL3I8VQA7JO3.pdf
https://www.camdencontrols.com/pipelines/resource/5986_CM_120TX_Manual_French_R1.pdf
https://www.camdencontrols.com/pipelines/resource/5987_9U3B8UPIHFT2XPCEYO4T.pdf
https://www.camdencontrols.com/pipelines/resource/5988_CM_120_Product_Comparison.pdf
https://www.camdencontrols.com/pipelines/resource/5989_SV3K7L7I325UY41Z2VJD.pdf
https://www.camdencontrols.com/pipelines/resource/5996_CM_120_Presentation.pdf
https://www.camdencontrols.com/pipelines/resource/5997_8P0IUZ3PNJ2V3VGH66JM.pdf

Reviews

There are no reviews yet.

Be the first to review “CM-120I – CM-120: Flush Mount Wired and Wireless Keypads”

Your email address will not be published. Required fields are marked *

CM-120TX battery operated wireless keypad leads the industry in performance, quality and value. ADA compliant and built to last, this rugged and versatile keypad features stainless steel faceplate, single gang flush mounting (enclosures are available for surface mount), 90,000 operations utilizing standard “AA” alkaline batteries and a complete range of programming features. The vandal-resistant all-metal keypad has blue backlighting for night time use.

Product specifications
Low-voltage wiring Required
BasisStructured, independently qualified product connection evidence
PreparationFit the keypad to a standard single-gang electrical box and route wiring out the rear so it cannot interfere with or short against the box sides. Complete the selected configuration wiring before fastening the assembly with the supplied machine or tamperproof screws. The foam gasket is specified for the outdoor CM-120W variant and is not assumed included with CM-120i. When directly switching a strike or magnetic lock, install the supplied MOV at the lock as shown. Choose standalone relay, Wiegand or optional TX-99 RF operation and program the corresponding functions; verify the actual board connections against the included diagram.
ElectricalStandalone operation uses a separate 12/24VAC/DC power input on power-block1/2, with 30mA standby and 90mA maximum documented draw. Each relay block is NO1/C2/NC3; use two conductors for common with one selected throw or three for both. Optional REX uses input-block1/2; optional door contact uses3/4, two conductors per selected input. The illustrated Wiegand configuration instead uses one typical seven-conductor shielded 22-gauge cable, maximum 250feet, including 12VDC controller power and Data1/Data0/redLED/greenLED/buzzer; preserve the ground connection shown. Wiegand selection disables both relays, RF outputs and REX. Optional TX-99 is a plug-in RF accessory and does not remove keypad operating-power wiring. Standalone field cable type, gauge, shielding and physical routes are not established by the Wiegand cable specification.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsCM-120i standalone operating power: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical routes unspecified for this standalone interface.; endpoints Compatible12/24VAC/DC operating supply to CM-120i separate power-block1/2; when Installation configuration is Standalone relay or optional RF configuration using a separate supply. The illustrated Wiegand cable includes operating power instead; do not add these alternatives.; Selected CM-120i relay1 common with NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical routes unspecified for this standalone interface.; endpoints Selected external low-voltage controlled circuit to CM-120i relay1 block 2 common and1 NO; when Installation configuration is Only when standalone relay1 is enabled and used with NO. Wiegand mode disables both relays; alternatives on the same pole are not additive.; Selected CM-120i relay1 common with NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical routes unspecified for this standalone interface.; endpoints Selected external low-voltage controlled circuit to CM-120i relay1 block 2 common and3 NC; when Installation configuration is Only when standalone relay1 is enabled and used with NC. Wiegand mode disables both relays; alternatives on the same pole are not additive.; Selected CM-120i relay1 common with NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical routes unspecified for this standalone interface.; endpoints Selected external low-voltage controlled circuit to CM-120i relay1 block 2 common,1 NO and3 NC; when Installation configuration is Only when standalone relay1 is enabled and used with NO and NC. Wiegand mode disables both relays; alternatives on the same pole are not additive.; Selected CM-120i relay2 common with NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical routes unspecified for this standalone interface.; endpoints Selected external low-voltage controlled circuit to CM-120i relay2 block 2 common and1 NO; when Installation configuration is Only when standalone relay2 is enabled and used with NO. Wiegand mode disables both relays; alternatives on the same pole are not additive.; Selected CM-120i relay2 common with NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical routes unspecified for this standalone interface.; endpoints Selected external low-voltage controlled circuit to CM-120i relay2 block 2 common and3 NC; when Installation configuration is Only when standalone relay2 is enabled and used with NC. Wiegand mode disables both relays; alternatives on the same pole are not additive.; Selected CM-120i relay2 common with NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical routes unspecified for this standalone interface.; endpoints Selected external low-voltage controlled circuit to CM-120i relay2 block 2 common,1 NO and3 NC; when Installation configuration is Only when standalone relay2 is enabled and used with NO and NC. Wiegand mode disables both relays; alternatives on the same pole are not additive.; CM-120i optional REX input: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical routes unspecified for this standalone interface.; endpoints Selected REX contact to CM-120i input-block1/2; when Installation configuration is Optional accessory selected: When REX is used in standalone mode; Wiegand mode disables this input.; CM-120i optional door contact input: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical routes unspecified for this standalone interface.; endpoints Selected door contact, closed when door is closed to CM-120i input-block3/4; when Installation configuration is Optional accessory selected: When the door-contact function is used in the standalone configuration shown.; CM-120i illustrated Wiegand controller cable: cable runs 1; 7 conductor(s); wire type 22 gauge shielded cable; size unspecified; shielding unspecified; rating Typical seven-conductor shielded 22-gauge cable, maximum 250feet, for this illustrated Wiegand connection only.; endpoints CM-120i power and Wiegand blocks to Compatible access-control controller12VDC/Data1/Data0/LED/buzzer terminals; when Installation configuration is Only the complete point-to-point Wiegand wiring configuration shown in diagram2: one seven-conductor shielded cable includes power and control signals. Maximum 250feet. Both relays, RF outputs and REX are disabled in Wiegand mode. Verify matching controller terminal functions.