Camden Door Controls CX-SA-1 switching network is an economical door interface relay. Relay 1 has an adjustable delay on release of 0 – 30 seconds. Relay 2 has a delay on operate of 0 – 30 seconds, and delay on release of 0 – 30 seconds.
| Low-voltage wiring | Required |
|---|---|
| Basis | Structured, independently qualified product connection evidence |
| Preparation | The unit mounts with double-sided foam tape and is a small wrap-around-sleeve module about 3/4 in (19 mm) deep, per the datasheet. Neither document states an explicit site preparation requirement, such as a box, cutout or prepared surface. Preparation is not determined from this evidence. |
| Electrical | The SA-1 is powered from 12 through 24 Volts, AC or DC, with no input polarity. Identify the delivered terminals by their labels: lock and operator relays each have C, NC and NO; inputs include +OUT, momentary trigger, extended trigger and GND REF. The momentary dry-contact circuit closes +OUT to MOM TRIG; the extended dry-contact circuit closes +OUT to EXTENDED TRIGGER. A powered trigger instead uses the corresponding trigger input and GND REF; its allowed range must match the actual board revision. Select dry or powered inputs for the intended interface rather than adding alternatives as extra cable runs. Each selected low-voltage input/contact loop needs two external conductors. The supplied MOV is local suppression across the lock relay contacts, not an additional field cable run. The manual combines MK5 and MKIV-labelled drawings with different terminal order, so follow labels on the delivered unit. Set lock, delay and operator timing and the selected latching/extended behavior, then test it. Choose field cable specification and routes for the actual circuit. |
| Preparation required | Yes |
| Electrical wiring required | Yes |
| Conditional connections | MOV (35 V varistor) across the lock relay contacts for back-EMF suppression: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Supplied MOV to Lock relay contact and lock supply circuit; when Installation configuration is Optional accessory selected: IF the supplied MOV is used to protect the relay contacts when switching an inductive lock. The MOV has no polarity. Whether it is a field cable connection or a local component connection is not documented.; CX-SA1 power input: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable gauge/type and physical route/run quantities require installation selection.; endpoints External matched AC/DC supply to Labelled power-input pair; when Installation configuration is Base power; non-polarized.; CX-SA1 momentary dry input: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable gauge/type and physical route/run quantities require installation selection.; endpoints External NO dry contact to +OUT and MOM TRIG; when Installation configuration is Selected dry trigger; alternative to powered trigger.; CX-SA1 extended dry input: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable gauge/type and physical route/run quantities require installation selection.; endpoints External maintained dry contact to +OUT and EXTENDED TRIGGER; when Installation configuration is Selected dry hold-open input; alternative to powered trigger.; CX-SA1 momentary powered input: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable gauge/type and physical route/run quantities require installation selection.; endpoints External compatible powered trigger to MOM TRIG and GND REF; when Installation configuration is Only selected powered trigger within delivered revision limits; alternative to dry input.; CX-SA1 extended powered input: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable gauge/type and physical route/run quantities require installation selection.; endpoints External compatible powered trigger to EXTENDED TRIGGER and GND REF; when Installation configuration is Only selected powered extended input within delivered limits; alternative to dry input.; CX-SA1 lock NO output: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable gauge/type and physical route/run quantities require installation selection.; endpoints Lock relay C and NO to External low-voltage lock control circuit; when Installation configuration is Selected NO lock circuit; NC alternative and full lock supply circuit require configuration.; CX-SA1 operator NO output: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable gauge/type and physical route/run quantities require installation selection.; endpoints Operator relay C and NO to External low-voltage operator input; when Installation configuration is Selected NO operator circuit; follow delivered terminal labels. |