Camden CX-IRB-6 – Isolation Relay Module, Package of 6

$75.00

Isolation Relay Module, Package of 6

SKU: CX-IRB-6
Category:
Brands:

Description

Series: CX-IRB

Type: Isolation Relay Module

Isolation Relay Module, Package of 6

Brand: Camden

Manufacturer Part Number: CX-IRB-6

Source: Camden Controls product page

Reviews

There are no reviews yet.

Be the first to review “Camden CX-IRB-6 – Isolation Relay Module, Package of 6”

Your email address will not be published. Required fields are marked *

The CX-IRB is Camden’s Double Pole Double Throw (DPDT) Isolation Relay. It can be used to aid any installer when dealing with integrations that provide excessive power sources or to isolate environmental issues such as electrical noise or induced voltages from unwanted sources. It can accept 12 or 24 VDC to operate.

Product specifications
Low-voltage wiring Connection count needs review
PreparationThis SKU is a package of six CX-IRB modules. Mount each selected module in the door-operator or other suitable electrical enclosure using the provided self-adhesive Velcro. Check actual clearance and terminal access. Set its JP1 jumper to the selected DC supply voltage before energizing. Installation circuit counts below are per installed module, not automatically multiplied by package quantity.
ElectricalEach CX-IRB module uses 12 or 24 VDC at V+ positive and V- negative/ground, with JP1 set to match. Its two independent changeover poles are labelled NC, C and NO; select C/NO or C/NC separately for each required low-voltage function. The power input and each selected contact loop need two external conductors per module. These are circuit counts, not physical cable jackets or package-wide totals. The manual and specification sheet disagree on current draw; confirm the delivered module and number used for supply sizing. Contact ratings are separate from coil supply. Choose field cable gauge/type, route and run quantities for the installed modules.
Conditional connectionsCX-IRB-6 module power input: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field gauge/type, route and physical run quantities require installation selection.; endpoints External matched DC supply to V+ and V- of installed module; when Installation configuration is Per installed module; set JP1 to supply voltage.; CX-IRB-6 module pole 1 NO output: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field gauge/type, route and physical run quantities require installation selection.; endpoints First pole C/NO to External low-voltage controlled circuit; when Installation configuration is Per module, only if pole1 NO function selected; NC alternative.; CX-IRB-6 module pole 2 NO output: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field gauge/type, route and physical run quantities require installation selection.; endpoints Second pole C/NO to Second external low-voltage controlled circuit; when Installation configuration is Per module, only if pole2 NO function selected; NC alternative.