The CX-1000/77 (MaxiMinder) is a timer that runs on 12 or 24 VDC and has an adjustable activation time from 1 second to 4 hours, triggering a DPDT relay via a normally open (or configurable normally closed) momentary trigger. It supports Timed Output mode and Delay on Release mode, for uses such as extended-duration lighting/door control, alarm shunting, and door operator hold-open functions.
| Power input | 12 or 24 VDC |
|---|---|
| Output contact rating | 12/24 VDC @ 4 amps (cut R4 for 24VDC operation) |
| Current draw | 12mA Idle / 60mA Peak |
| Low-voltage wiring | Required |
| Basis | Structured, independently qualified product connection evidence |
| Preparation | The supplied documents do not state mounting, enclosure, box depth or cutout requirements. Documented setup steps (DIP switch settings, and cutting R4 for 24 VDC operation) are product configuration, not site preparation. A power source is needed, but no preparation requirement is documented. |
| Electrical | Power input is 12 or 24 VDC at the + and ground terminals. The manual requires cutting R4 for 24 VDC operation; confirm the actual board revision before configuring it. External timed-output mode uses T to ground through the selected trigger contact; the illustrated normally-open configuration uses S1 OFF and S2 OFF. In power-up delay mode the supply itself triggers timing and T is unused. The DPDT output has two separate C/NC/NO poles; select the required contact state for each used pole. Each selected external low-voltage contact loop needs two conductors. The contact rating is separate from power input. Set operating mode, seconds/minutes and required time; verify the selected application rather than copying another example. Field cable specification, routing and physical run quantities remain installation decisions. |
| Electrical wiring required | Yes |
| Conditional connections | CX-1000/77 power input: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable specification and physical route/run quantity require installation selection.; endpoints External DC supply to Timer + and ground; when Installation configuration is Match supply and R4 configuration.; CX-1000/77 external NO trigger: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable specification and physical route/run quantity require installation selection.; endpoints External normally-open contact to T and ground; when Installation configuration is S1 OFF and S2 OFF timed-output mode only; omitted for power-up delay.; CX-1000/77 first pole NO output: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable specification and physical route/run quantity require installation selection.; endpoints First pole C and NO to External low-voltage controlled circuit; when Installation configuration is Selected first pole NO circuit; NC is an alternative.; CX-1000/77 second pole NO output: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable specification and physical route/run quantity require installation selection.; endpoints Second pole C and NO to Second external low-voltage controlled circuit; when Installation configuration is Only when second DPDT pole is used; NC is an alternative. |