| handing | LH, Non-handed, RH |
|---|---|
| finish | 628, 710, 711 |
| arm | LNGTLS2, LONG2, REG/STD, REGARM2, STDTRACKARM2, TLS/STD, TLS2 |
| Low-voltage wiring | Connection count needs review |
|---|---|
| Preparation | Check the approved opening drawings and header clearances. Prepare header wire-access holes for the selected surface installation using template 740070. For mounting onto a 2-inch frame, consult the manufacturer to determine whether a mounting plate is required. |
| Electrical | For the documented 120 VAC configuration, provide a dedicated single-phase 60 Hz supply fused at 15 A at the side jamb, with approximately 12 inches of wire available to connect the operator. The manufacturer specifies a 3-wire supply and recommends UL-approved flexible conduit. The legacy model reference also lists an optional 240 V configuration; these 120 V instructions do not establish its wiring requirements. Accessory activation, safety and locking connections depend on the selected devices. |
| Preparation required | Yes |
| Electrical wiring required | Yes |
| Conditional connections | 120 VAC field power supply at side jamb to operator: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Dedicated mains circuit at side jamb to Operator AC supply connection and header earth; when Installation configuration is IF the legacy operator is configured for the 120 VAC supply covered by manual 740132. Three field supply conductors per connection; this is not a total cable-run count. Optional 240 V configurations and accessory circuits are not established by this count.; Selected activation, safety and locking accessory circuits: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Senior Swing control box to Selected activation, safety or locking device; when Installation configuration is Optional accessory selected: IF an activation, safety or locking accessory is selected, follow its own instructions. Conductor counts and cable-run quantities remain unknown here.; 120 V AC power supply to the operator, from the side-jamb supply conduit into the header for final hookup: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints 120 V dedicated branch circuit at side jamb to operator in header; when Installation configuration is Base operator at 115/120 V, in the surface or concealed configuration covered by the Senior Swing instructions. The 9553 is covered through the 9500/9550 surface-series scope. The supply is a 120 V, single-phase, 60 Hz, fused 15 A, 3-wire dedicated circuit. About 12 in of wire is to be left inside the header. The number of cable runs and the conductor count for the field cable are not documented here. |