LCN 9531 Operator

$350.00

SKU: 9531
Category:
Brands:

Additional information

handing

LH, RH

finish

628, 710, 711

voltage

115V, 230V

arm

STD

Reviews

There are no reviews yet.

Be the first to review “LCN 9531 Operator”

Your email address will not be published. Required fields are marked *

The manifest's sole item (id 4850, sku '9531', title 'LCN 9531 Operator') corresponds to the LCN 9531IQ, the single-door surface-mount model within LCN's 9530IQ Series of heavy-duty electromechanical automatic swing-door operators ('Senior Swing'). This was confirmed via the official 9530IQ Series ordering guide, whose 'How to Order a 9530IQ Series Operator' table lists '9531IQ' as the operator selection under a single-door, surface-mount, offset-pivot, pull-side, handed configuration capable of operating doors up to 600 lb. A dedicated 9531/9530IQ installation or wiring manual (with field low-voltage wiring/AWG guidance) was not located in this research pass; only the product data sheet/ordering guide was found.

Product specifications
Certifications Grade 1 – ANSI A156.19, UL325, UL228, UL10C, ADA, 100 Hour Salt Spray, CSFM, Meets BAA (Buy American Act)
Door width 33 inch minimum to 48 inch maximum (single leaf)
Door weight up to 600 lb
Power input 115VAC single phase @60Hz, or 230VAC single phase @50Hz
Power output 2A @ 24VDC (on-board supply, used to power actuators, card readers, and safety circuits)
Mounting single door, surface mount, offset pivot, butt hinge, pull side
Warranty 2 years
Low-voltage wiring Connection count needs review
PreparationCheck the approved opening drawings and header clearances. Prepare header wire-access holes for the selected surface installation using template 740070. For mounting onto a 2-inch frame, consult the manufacturer to determine whether a mounting plate is required.
ElectricalFor the documented 120 VAC configuration, provide a dedicated single-phase 60 Hz supply fused at 15 A at the side jamb, with approximately 12 inches of wire available to connect the operator. The manufacturer specifies a 3-wire supply and recommends UL-approved flexible conduit. The legacy model reference also lists an optional 240 V configuration; these 120 V instructions do not establish its wiring requirements. Accessory activation, safety and locking connections depend on the selected devices.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connections120 VAC field power supply at side jamb to operator: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Dedicated mains circuit at side jamb to Operator AC supply connection and header earth; when Installation configuration is IF the legacy operator is configured for the 120 VAC supply covered by manual 740132. Three field supply conductors per connection; this is not a total cable-run count. Optional 240 V configurations and accessory circuits are not established by this count.; Selected activation, safety and locking accessory circuits: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Senior Swing control box to Selected activation, safety or locking device; when Installation configuration is Optional accessory selected: IF an activation, safety or locking accessory is selected, follow its own instructions. Conductor counts and cable-run quantities remain unknown here.