Camden CX-EPD1289L-BK – All-black finish, 3/4″ surface mount Grade 1 RIM strike with preload, 12/24V, AC/DC, fail safe/fail secure, c/w ‘plug-in’ latch monitor assembly and metal mounting jig

$50.00

All-black finish, 3/4\” surface mount Grade 1 RIM strike with preload, 12/24V, AC/DC, fail safe/fail secure, c/w ‘plug-in\’ latch monitor assembly and metal mounting jig

SKU: CX-EPD1289L-BK
Category:
Brands:

Description

Series: CX-EPD1289L

Type: 3/4" Surface Mount Preload RIM Strike

All-black finish, 3/4" surface mount Grade 1 RIM strike with preload, 12/24V, AC/DC, fail safe/fail secure, c/w ‘plug-in' latch monitor assembly and metal mounting jig

Brand: Camden

Manufacturer Part Number: CX-EPD1289L-BK

Source: Camden Controls product page

Reviews

There are no reviews yet.

Be the first to review “Camden CX-EPD1289L-BK – All-black finish, 3/4″ surface mount Grade 1 RIM strike with preload, 12/24V, AC/DC, fail safe/fail secure, c/w ‘plug-in’ latch monitor assembly and metal mounting jig”

Your email address will not be published. Required fields are marked *

The CX-EPD1289L is Camden's surface-mount RIM electric strike with preload capability (up to 15 lbs / 6.8 kg), the first of its kind in the industry, offering a Grade 1 'universal' design with removable latch monitoring switch, field-selectable 12/24V AC/DC operation and fail-safe/fail-secure operation. It is available in stainless steel or all-black finish and is UL fire and burglary rated.

Product specifications
Latch projection 3/4" (1.9cm)
Voltage 12/24V AC/DC
Current draw 560mA @ 12VDC | 280mA @ 24VDC
Static force 1,500 Lbs / 680 Kg (UL Verified)
Preload 15 Lbs / 6.8 Kg
Endurance 1,500,000 Cycles (factory tested); 250,000 Cycles (UL Verified)
Fire rating UL10C/CAN4-S104, 3 hr (fail-secure mode only)
Low-voltage wiring Connection count needs review
PreparationAlign the installation jig with the actual jamb and RIM latch centerline. Check door alignment and strike clearance before marking. Remove the jig, punch pilot holes, then drill the 9/16 inch wiring hole and 7/32 inch mounting holes shown on the exact template. Feed wires without pulling or pinching. Initially fit the top and bottom 1/4-20 x 1-1/4 inch screws loosely, align and test latch movement, then mark and drill the middle mounting holes and secure all four screws. Fit the appropriate spacer arrangement only as required by the actual gap. Attach the latch monitor and cover with the four M3 x 6 screws after verifying wiring and operation. Confirm the required fail-safe or fail-secure mode before commissioning; the manual describes fail-secure as the default.
ElectricalUse the matched 12/24V AC/DC supply and the corresponding pre-wired power connector. The selected external power circuit uses two field conductors. For 12V hardwiring, red/black join the positive supply and blue/green join the negative; for 24V, red is positive and green negative, with black/blue joined locally. Connect the supplied MOV across the supply inputs. Factory leads and the local jumper remain local; physical cable jackets and routes require installation design. The latch-monitor contact is orange COM, white NO and grey NC. A selected COM/NO or COM/NC external low-voltage monitoring loop uses two conductors; use three only if the controller actually requires COM and both throws. Its SPDT 100mA at 24V DC resistive rating is a contact limit, not a monitor supply requirement. Select monitoring logic, operating mode, cable specification and physical run quantities for the installation.
Preparation requiredYes
Conditional connectionsCX-EPD1289L-BK selected supply: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Cable selection, physical routes and run quantities require installation design.; endpoints External matched low-voltage supply to Selected strike power connector; when Installation configuration is Choose matched 12V or 24V connector; voltage alternatives describe one installed power circuit.; CX-EPD1289L-BK selected monitor loop: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Cable selection, physical routes and run quantities require installation design.; endpoints Monitor orange COM and selected white NO or grey NC to External low-voltage monitoring input; when Installation configuration is If monitoring uses COM with either NO or NC; alternative to both-throw connection.; CX-EPD1289L-BK both-throw monitor: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Cable selection, physical routes and run quantities require installation design.; endpoints Monitor orange COM white NO grey NC to External low-voltage both-throw monitoring inputs; when Installation configuration is Only if external controller requires COM, NO and NC; alternative to selected single contact loop.

Official manufacturer documents