Camden CM-1270 – Key Switch, SPDT Momentary and SPDT Maintained

$75.00

Key Switch, SPDT Momentary and SPDT Maintained

SKU: CM-1270
Category:
Brands:

Description

Series: CM-1200 & CM-2200 Series

Type: Stainless Steel, Flush mount

Configuration: Single Gang Faceplate

Key Switch, SPDT Momentary and SPDT Maintained

Brand: Camden

Manufacturer Part Number: CM-1270

Source: Camden Controls product page

Reviews

There are no reviews yet.

Be the first to review “Camden CM-1270 – Key Switch, SPDT Momentary and SPDT Maintained”

Your email address will not be published. Required fields are marked *

Camden Door Controls CM-1200 and CM-2200 Series flush mount key switches meet the demands of key switch controls, designed for use with standard 1", 1-1/8", or 1-1/4" mortise cylinders. CM-1200 is single gang (2-3/4" wide) and CM-2200 is narrow style (1-3/4" wide); both accept one or two switches and control overhead doors, electric locks, electro-magnetic locks, electric strikes, and motors.

Product specifications
Faceplate heavy duty stainless steel
Input voltage 12-24V AC/DC
Contact rating standard 6 A @ 30VDC
Contact rating optional 15 A @ 30VDC
Lead wire 18 AWG color coded soldered leads
Mortise cylinder size 1", 1-1/8", or 1-1/4"
Width (CM-1200) 2-3/4" (70mm)
Width (CM-2200) 1-3/4" (44mm)
Included hardware brass cylinder lock ring, 2 socket/slotted screws, 2 tamperproof screws with driver
Low-voltage wiring Required
BasisStructured, independently qualified product connection evidence
PreparationFit the aluminum bracket against the stud behind the faceplate. Insert the separately purchased mortise cylinder from the front and align its side grooves with the bracket retainers. If irregular grooves prevent fitting, file the retainers slightly; never remove them completely. Tighten the brass cylinder lock ring to secure the bracket. Fit the supplied switch in the selected bracket hole with its spacer ring and threaded washer. Align the cam centrally over the switch and check key operation before fastening the unit to the selected switch box, wall or receptacle box with the supplied screws. Select the mounting arrangement and compatible cylinder for the installation.
ElectricalBase configuration: Key Switch, SPDT Momentary and SPDT Maintained. For each used changeover pole, common plus NO or common plus NC requires two external conductors; common plus both NO and NC requires three. Apply that choice separately to each of the two supplied switches. Do not join independent commons by assumption. These are low-voltage circuit conductor counts, not physical cable-run counts. The supplied 18 AWG soldered leads do not specify field cable gauge. Common is grey; momentary NO is blue and NC orange. The maintained-contact chart lists both throw leads orange, so identify the actual terminal function before connecting. Cable type, gauge, shielding and physical run quantities depend on the selected controller/device and site routing. Optional LED circuits remain separate and require their selected DC option instructions. The standard-contact parts table and family specification give different contact ratings; verify the fitted switch rating. Contact ratings are not supply requirements.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsSwitch contact connection for the SPDT maintained switch (common, N.O., N.C. leads); this is the factory soldered lead set, not a field cable: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints SPDT maintained switch leads (grey common, orange N.O., orange N.C.) to external controlled circuit (site-dependent); when Installation configuration is Internal accessory connection; not field cable: Base CM-1270 SPDT maintained switch. The wiring table gives the maintained SPDT colours as grey common, orange normally open and orange normally closed. The external cable run and its core count are not documented.; Switch contact connection for the SPDT momentary switch (common, N.O., N.C. leads); this is the factory soldered lead set, not a field cable: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints SPDT momentary switch leads (grey common, blue N.O., orange N.C.) to external controlled circuit (site-dependent); when Installation configuration is Internal accessory connection; not field cable: Base CM-1270 SPDT momentary switch. The wiring table gives the momentary SPDT colours as grey common, blue normally open and orange normally closed. The external cable run and its core count are not documented.; Optional LED indicator circuit: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints LED red (+) lead to LED black (-) lead to 12 VDC or 24 VDC DC supply; when Installation configuration is Internal accessory connection; not field cable: Optional accessory selected: IF an optional LED indicator (-70xx suffix) is selected. The LEDs are DC only; the 24 V versions use a 1.5 k ohm resistor in the circuit. This is not part of the base switch.; Selected base switch 1: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1270 switch 1 common and NO; when Installation configuration is For switch 1, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1270 switch 1 common and NC; when Installation configuration is For switch 1, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1270 switch 1 common, NO and NC; when Installation configuration is For switch 1, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1270 switch 2 common and NO; when Installation configuration is For switch 2, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1270 switch 2 common and NC; when Installation configuration is For switch 2, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1270 switch 2 common, NO and NC; when Installation configuration is For switch 2, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.