Camden CM-1260 – Key Switch, (2) SPDT Maintained

$75.00

Key Switch, (2) SPDT Maintained

SKU: CM-1260
Category:
Brands:

Description

Series: CM-1200 & CM-2200 Series

Type: Stainless Steel, Flush mount

Configuration: Single Gang Faceplate

Key Switch, (2) SPDT Maintained

Brand: Camden

Manufacturer Part Number: CM-1260

Source: Camden Controls product page

Reviews

There are no reviews yet.

Be the first to review “Camden CM-1260 – Key Switch, (2) SPDT Maintained”

Your email address will not be published. Required fields are marked *

Camden Door Controls CM-1200 and CM-2200 Series flush mount key switches meet the demands of key switch controls, designed for use with standard 1", 1-1/8", or 1-1/4" mortise cylinders. CM-1200 is single gang (2-3/4" wide) and CM-2200 is narrow style (1-3/4" wide); both accept one or two switches and control overhead doors, electric locks, electro-magnetic locks, electric strikes, and motors.

Product specifications
Faceplate heavy duty stainless steel
Input voltage 12-24V AC/DC
Contact rating standard 6 A @ 30VDC
Contact rating optional 15 A @ 30VDC
Lead wire 18 AWG color coded soldered leads
Mortise cylinder size 1", 1-1/8", or 1-1/4"
Width (CM-1200) 2-3/4" (70mm)
Width (CM-2200) 1-3/4" (44mm)
Included hardware brass cylinder lock ring, 2 socket/slotted screws, 2 tamperproof screws with driver
Low-voltage wiring Required
BasisStructured, independently qualified product connection evidence
PreparationFit the aluminum bracket against the stud behind the faceplate. Insert the separately purchased mortise cylinder from the front and align its side grooves with the bracket retainers. If irregular grooves prevent fitting, file the retainers slightly; never remove them completely. Tighten the brass cylinder lock ring to secure the bracket. Fit the supplied switch in the selected bracket hole with its spacer ring and threaded washer. Align the cam centrally over the switch and check key operation before fastening the unit to the selected switch box, wall or receptacle box with the supplied screws. Select the mounting arrangement and compatible cylinder for the installation.
ElectricalBase configuration: Key Switch, (2) SPDT Maintained. For each used changeover pole, common plus NO or common plus NC requires two external conductors; common plus both NO and NC requires three. Apply that choice separately to each of the two supplied switches. Do not join independent commons by assumption. These are low-voltage circuit conductor counts, not physical cable-run counts. The supplied 18 AWG soldered leads do not specify field cable gauge. Common is grey; momentary NO is blue and NC orange. The maintained-contact chart lists both throw leads orange, so identify the actual terminal function before connecting. Cable type, gauge, shielding and physical run quantities depend on the selected controller/device and site routing. Optional LED circuits remain separate and require their selected DC option instructions. The standard-contact parts table and family specification give different contact ratings; verify the fitted switch rating. Contact ratings are not supply requirements.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsOptional LED indicator circuit (12 VDC or 24 VDC, DC only) with red and black leads: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints optional LED red (+) and black (−) leads to external DC supply (12 VDC or 24 VDC); when Installation configuration is Optional accessory selected: IF an optional LED indicator is selected (ordered with the -70xx, -71xx, -72xx or -74xx suffix). Not part of the base CM-1260. The 24 VDC LED is shown with a 1.5 k ohm resistor in the circuit, and the 12 VDC LED has an integrated 560 ohm resistor. A bi-colour (3 wire) LED is a separate optional configuration. The LED leads' cable run count is not documented.; Selected base switch 1: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1260 switch 1 common and NO; when Installation configuration is For switch 1, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1260 switch 1 common and NC; when Installation configuration is For switch 1, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1260 switch 1 common, NO and NC; when Installation configuration is For switch 1, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1260 switch 2 common and NO; when Installation configuration is For switch 2, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1260 switch 2 common and NC; when Installation configuration is For switch 2, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1260 switch 2 common, NO and NC; when Installation configuration is For switch 2, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.

Official manufacturer documents