Description
Series: CM-1100 & CM-2000 Series
Type: Cast Aluminum, Flush Mount
Configuration: Single Gang Faceplate
Key Switch, SPDT N/O & N/C Maintained
Brand: Camden
Manufacturer Part Number: CM-1130
Source: Camden Controls product page
Series: CM-1100 & CM-2000 Series
Type: Cast Aluminum, Flush Mount
Configuration: Single Gang Faceplate
Key Switch, SPDT N/O & N/C Maintained
Brand: Camden
Manufacturer Part Number: CM-1130
Source: Camden Controls product page
Camden Door Controls, CM-1100 and CM-2000 Series flush mount key switches meet the stringent demands of key switch controls. They are designed for use with standard 1”, 1 1/8”, or 1 1/4” mortise cylinders. Fabricated from 1/4” thick aluminum, into a one piece die cast construction, with unique Camden Manufacturing features.
| Low-voltage wiring | Required |
|---|---|
| Basis | Structured, independently qualified product connection evidence |
| Preparation | The CM-1130 is a flush-mount, single-gang key switch. It accepts a standard mortise cylinder of 1 inch to 1-1/4 inch, and the cylinder is a separate item in the optional cylinder list. The manual lists compatible CM-1100 series mounting boxes. Faceplate dimensions are 4-1/2 in x 2-3/4 in x 1-1/2 in. The documents do not say which mounting method applies at a particular site. |
| Electrical | Base configuration: Key Switch, SPDT N/O & N/C Maintained. For each used changeover pole, common plus NO or common plus NC requires two external conductors; common plus both NO and NC requires three. Do not join independent commons by assumption. These are low-voltage circuit conductor counts, not physical cable-run counts. The supplied 18 AWG soldered leads do not specify field cable gauge. Common is grey; momentary NO is blue and NC orange. The maintained-contact chart lists both throw leads orange, so identify the actual terminal function before connecting. Cable type, gauge, shielding and physical run quantities depend on the selected controller/device and site routing. Optional LED circuits remain separate and require their selected DC option instructions. The standard-contact parts table and family specification give different contact ratings; verify the fitted switch rating. Contact ratings are not supply requirements. |
| Preparation required | Yes |
| Electrical wiring required | Yes |
| Conditional connections | Selected base switch 1: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1130 switch 1 common and NO; when Installation configuration is For switch 1, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1130 switch 1 common and NC; when Installation configuration is For switch 1, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1130 switch 1 common, NO and NC; when Installation configuration is For switch 1, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred. |