The manifest's sole item (id 4850, sku '9531', title 'LCN 9531 Operator') corresponds to the LCN 9531IQ, the single-door surface-mount model within LCN's 9530IQ Series of heavy-duty electromechanical automatic swing-door operators ('Senior Swing'). This was confirmed via the official 9530IQ Series ordering guide, whose 'How to Order a 9530IQ Series Operator' table lists '9531IQ' as the operator selection under a single-door, surface-mount, offset-pivot, pull-side, handed configuration capable of operating doors up to 600 lb. A dedicated 9531/9530IQ installation or wiring manual (with field low-voltage wiring/AWG guidance) was not located in this research pass; only the product data sheet/ordering guide was found.
| Certifications | Grade 1 – ANSI A156.19, UL325, UL228, UL10C, ADA, 100 Hour Salt Spray, CSFM, Meets BAA (Buy American Act) |
|---|---|
| Door width | 33 inch minimum to 48 inch maximum (single leaf) |
| Door weight | up to 600 lb |
| Power input | 115VAC single phase @60Hz, or 230VAC single phase @50Hz |
| Power output | 2A @ 24VDC (on-board supply, used to power actuators, card readers, and safety circuits) |
| Mounting | single door, surface mount, offset pivot, butt hinge, pull side |
| Warranty | 2 years |
| Low-voltage wiring | Connection count needs review |
| Preparation | Check the approved opening drawings and header clearances. Prepare header wire-access holes for the selected surface installation using template 740070. For mounting onto a 2-inch frame, consult the manufacturer to determine whether a mounting plate is required. |
| Electrical | For the documented 120 VAC configuration, provide a dedicated single-phase 60 Hz supply fused at 15 A at the side jamb, with approximately 12 inches of wire available to connect the operator. The manufacturer specifies a 3-wire supply and recommends UL-approved flexible conduit. The legacy model reference also lists an optional 240 V configuration; these 120 V instructions do not establish its wiring requirements. Accessory activation, safety and locking connections depend on the selected devices. |
| Preparation required | Yes |
| Electrical wiring required | Yes |
| Conditional connections | 120 VAC field power supply at side jamb to operator: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Dedicated mains circuit at side jamb to Operator AC supply connection and header earth; when Installation configuration is IF the legacy operator is configured for the 120 VAC supply covered by manual 740132. Three field supply conductors per connection; this is not a total cable-run count. Optional 240 V configurations and accessory circuits are not established by this count.; Selected activation, safety and locking accessory circuits: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Senior Swing control box to Selected activation, safety or locking device; when Installation configuration is Optional accessory selected: IF an activation, safety or locking accessory is selected, follow its own instructions. Conductor counts and cable-run quantities remain unknown here. |