Description
Series: CX-IRB
Type: Isolation Relay Module
Isolation Relay Module
Brand: Camden
Manufacturer Part Number: CX-IRB
Source: Camden Controls product page
Series: CX-IRB
Type: Isolation Relay Module
Isolation Relay Module
Brand: Camden
Manufacturer Part Number: CX-IRB
Source: Camden Controls product page
The CX-IRB is Camden’s Double Pole Double Throw (DPDT) Isolation Relay. It can be used to aid any installer when dealing with integrations that provide excessive power sources or to isolate environmental issues such as electrical noise or induced voltages from unwanted sources. It can accept 12 or 24 VDC to operate.
| Low-voltage wiring | Required |
|---|---|
| Basis | Structured, independently qualified product connection evidence |
| Preparation | The module must be mounted in a suitable location (e.g. door operator or electrical enclosure or power supply cabinet) with enough space for its stated dimensions. The JP1 jumper must be set to the supply voltage (12 or 24 VDC), and a 12/24 VDC supply must be available to operate it. Self-adhesive Velcro tape is stated as provided for mounting. |
| Electrical | Select 12 or 24VDC operating input and set JP1 to match before energizing. Connect positive to V+ and negative/GND to V-; this operating-power interface uses two conductors and draws 40mA at the documented input voltages. The DPDT relay has two independent poles, each labelled NC, C and NO. For each used low-voltage pole, C with one selected throw uses two conductors, or C with both throws uses three. Do not bridge pole commons or sum alternative configurations. Contact ratings describe the controlled circuit, not a second operating supply. Field cable type, gauge, shielding and physical run quantities require the connected equipment requirements and site routing. |
| Preparation required | Yes |
| Electrical wiring required | Yes |
| Conditional connections | CX-IRB selected operating power V+ and V-: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Supply cable gauge, type, shielding and physical route unspecified.; endpoints Selected 12/24VDC operating supply to CX-IRB V+ and V-; when Installation configuration is Set JP1 to match selected 12 or 24VDC input; applying voltage energizes the relay. Respect polarity.; Selected CX-IRB upper pole C and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Controlled-circuit field cable type, gauge, shielding and physical routes unspecified.; endpoints Selected external low-voltage controlled circuit to CX-IRB upper terminal row C and NO; when Installation configuration is When the upper independent pole is used with C and NO. Alternatives on the same pole are not additive; the other pole remains independent.; Selected CX-IRB upper pole C and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Controlled-circuit field cable type, gauge, shielding and physical routes unspecified.; endpoints Selected external low-voltage controlled circuit to CX-IRB upper terminal row C and NC; when Installation configuration is When the upper independent pole is used with C and NC. Alternatives on the same pole are not additive; the other pole remains independent.; Selected CX-IRB upper pole C, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Controlled-circuit field cable type, gauge, shielding and physical routes unspecified.; endpoints Selected external low-voltage controlled circuit to CX-IRB upper terminal row C, NO and NC; when Installation configuration is When the upper independent pole is used with C, NO and NC. Alternatives on the same pole are not additive; the other pole remains independent.; Selected CX-IRB lower pole C and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Controlled-circuit field cable type, gauge, shielding and physical routes unspecified.; endpoints Selected external low-voltage controlled circuit to CX-IRB lower terminal row C and NO; when Installation configuration is When the lower independent pole is used with C and NO. Alternatives on the same pole are not additive; the other pole remains independent.; Selected CX-IRB lower pole C and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Controlled-circuit field cable type, gauge, shielding and physical routes unspecified.; endpoints Selected external low-voltage controlled circuit to CX-IRB lower terminal row C and NC; when Installation configuration is When the lower independent pole is used with C and NC. Alternatives on the same pole are not additive; the other pole remains independent.; Selected CX-IRB lower pole C, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Controlled-circuit field cable type, gauge, shielding and physical routes unspecified.; endpoints Selected external low-voltage controlled circuit to CX-IRB lower terminal row C, NO and NC; when Installation configuration is When the lower independent pole is used with C, NO and NC. Alternatives on the same pole are not additive; the other pole remains independent. |