Von Duprin 6225 – Mortise/cylindrical strike, 9″ faceplate; own Folger Adam

$50.00

Mortise/cylindrical strike, 9″ faceplate; own Folger Adam FA310-2 OB Variant record generated from manufacturer nomenclature (https://us.allegion.com/content/dam/allegion-us-2/web-files/von-duprin-/information-documents/Von_Duprin_6200_Series_Data_Sheet_105368.pdf); price inherited from product #4818 pending owner confirmation.

SKU: 6225
Category:
Brands:

Description

Mortise/cylindrical strike, 9″ faceplate; own Folger Adam FA310-2 OB Variant record generated from manufacturer nomenclature (https://us.allegion.com/content/dam/allegion-us-2/web-files/von-duprin-/information-documents/Von_Duprin_6200_Series_Data_Sheet_105368.pdf); price inherited from product #4818 pending owner confirmation.

Reviews

There are no reviews yet.

Be the first to review “Von Duprin 6225 – Mortise/cylindrical strike, 9″ faceplate; own Folger Adam”

Your email address will not be published. Required fields are marked *

Product specifications
Low-voltage wiring Connection count needs review
PreparationPrepare the door for the exact 6225 open-back strike using its door-preparation template; follow lock/device instructions. Deadbolt operation is not supported.
Electrical6200 Series supply options: 12V DC, 16V DC, 24V DC, 28V DC, continuous duty. Match the supply to the strike's ordered voltage; the all-model table does not identify the voltage of this catalogue item.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsAC supply via rectifier kit: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints AC supply to Rectifier kit (J1, P1A, J1A) to Solenoid (P1); when Installation configuration is Optional accessory selected: IF AC power is required and the optional rectifier kit (S012 or S024) is selected.; Scoped installation connections for 6225: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating Only the separately documented plain DC interface has a verified conductor count. Other option circuits and cable-run quantities remain unknown.; endpoints 6225 selected power connector and supported optional circuits to Selected external supply and control/monitor equipment; when Installation configuration is Base power: Connect the external supply to the strike solenoid via the documented power connector path; match the ordered solenoid voltage. Dc: Use direct DC wiring for the matching DC solenoid. Ac: Only with the matching rectifier: S012 converts 12 VAC to 12 VDC; S024 converts 24 VAC to 24 VDC. Mode: FSE requires power to unlock and remains locked on power loss; FS requires power to lock and unlocks on power loss. Preserve the actual ordered configuration. Optional eb: Entry buzzer only when ordered, and only in FSE configuration. Monitor scope: Current exact-model table does not offer DS/DS-LC for this model; no monitoring circuit is proposed.; Plain DC supply connection at the external power interface: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Match the ordered DC coil and connector; additional optional circuits require their own supported configuration.; endpoints External 12 VDC or 24 VDC supply interface/J1 to Strike power connector P1; when Installation configuration is Only the plain DC circuit with the selected matching 12 VDC or 24 VDC solenoid/connector. Two conductors at this external supply interface. No buzzer, DS/DS-LC monitoring or AC rectifier branch is included. This is not a total installation count or a cable-run/new-pull quantity.