Description
Comes with 8310-877 Header
Mount Safety Sensor
Model 8310-846. Installer-grade handheld remote control.
Comes with 8310-877 Header
Mount Safety Sensor
| Brand | LCN |
|---|
LCN 8310 Series is a modular system of touchless and push-plate door actuators, wireless transmitter/receiver sets, mounting boxes, escutcheons, weather/trim rings, safety sensors, and accessory kits used to remotely actuate LCN automatic swing-door operators (e.g., 4630/4640, 7900 pneumatic auto-equalizer, 9100 Benchmark, Senior Swing 2800/9500, Mid Swing 2900/9700 series). Touchless actuators and hardwired push plates require a wired, low-voltage power/control connection back to the door operator control box; most are also compatible with a 433 MHz or 900 MHz wireless transmitter/receiver pair for wireless actuation signaling instead of a run of activation wire. A subset of push plates (8310-852WP/853WP) are fully wireless/battery powered with no field control wiring at the plate itself (only the receiver, sold separately, is wired to the operator).
| Touchless actuator supply (8310-813) | 12-24 VAC ±10% or 12-24 VDC +30%/-10%, SELV-compatible power supplies only; power consumption < 1.5W; output is a voltage-free relay (max 60VDC/125VAC, 1A resistive, 30W) |
|---|---|
| 900 MHz receiver input voltage (8310-880) | 12-24 VAC/VDC; relay contact rating 1.0A@30VDC, 0.3A@60VDC, 0.5A@125VAC |
| Wireless transmitter power consumption (900 MHz) | 30mA (standard TX) / 40mA (RX) / 22mA (retrofit TX) |
| Receiver capacity | up to 74-75 transmitters per standard receiver; unlimited for 'universal' mode |
| Low-voltage wiring | Required |
| Basis | Structured, independently qualified product connection evidence |
| Preparation | Prepare the harness route from the8310-877 header sensor through the wire-passage hole into the header, then route the supplied cable to the automatic door control. Keep the sensor and controller connectors intact for the illustrated compatible SeniorSwing installation. Other controller connections must follow their own matching diagram. |
| Electrical | Use the8310-846 header-mount harness with the8310-877 sensor. In the illustrated compatible SeniorSwing configuration, it is one supplied six-conductor cable assembly, with the white10-position sensor connector and black6-position controllerP1 connector. Do not use the crossed-out7-terminal connector. Other operators require the matching wiring diagram before removing the controller plug. The manufacturer lists a4ft cable; conductor gauge and shielding are not stated. This supplied harness is separate from any additional field extension or cable pull. |
| Preparation required | Yes |
| Electrical wiring required | Yes |
| Conditional connections | Supplied low-voltage877-to-SeniorSwing harness: cable runs 1; 6 conductor(s); wire type Manufacturer-supplied header-sensor harness. Gauge and shielding not specified.; size unspecified; shielding unspecified; rating Manufacturer-supplied header-mount harness; six conductors, one4ft cable assembly per sensor. Gauge/shielding not specified. Use the actual controller diagram75.5546 and compatible harness; additional site runs are separate.; endpoints 8310-877 white10-position sensor connector to Compatible SeniorSwing controllerP1 black6-position connector; when Installation configuration is Only the supplied header-sensor harness and compatible SeniorSwing P1 interface illustrated on original877 manual page5. One physical supplied harness assembly per sensor, with six populated conductors. Not the crossed-out7-terminal connector, not other controllers, not additional field cable pulls or a whole-system conductor total. |
Reviews