Centerline electric strike for aluminum and wood frames Variant record generated from manufacturer nomenclature (https://www.dormakaba.com/us-en/offering/products/electronic-access-data/electric-strikes/rci-f1114f1119-centerline–ka_500259); price inherited from product #5122 pending owner confirmation.

SKU: F1119
Category:
Brands:

Description

Centerline electric strike for aluminum and wood frames Variant record generated from manufacturer nomenclature (https://www.dormakaba.com/us-en/offering/products/electronic-access-data/electric-strikes/rci-f1114f1119-centerline–ka_500259); price inherited from product #5122 pending owner confirmation.

Reviews

There are no reviews yet.

Be the first to review “Dormakaba F1119 – Centerline electric strike for aluminum and wood frames”

Your email address will not be published. Required fields are marked *

Product specifications
Low-voltage wiring Connection count needs review
PreparationThe F1119 has a documented 1-3/4" (45mm) insert depth and a 1-3/8" W x 9" H (34mm x 229mm) faceplate, so the frame needs a prepared cutout and depth for it. The strike is saddle-mounted, and mounting tabs, shims and fasteners are included. The source does not give the cutout dimensions or the frame preparation procedure.
ElectricalThe source gives an electrical rating of 200mA at 11-16VAC, 12VAC/VDC or 24VAC/VDC (max at 12VDC) for this electric strike. It does not describe the terminals, leads, wire gauge, or the number of field cable runs.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsIncoming power supply wiring to the strike insert terminal screws: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints power supply to strike insert terminal screws; when Installation configuration is Base product. Applies when making the field power connection to the strike. The document does not state the cable count or conductor count. The strike is not polarity sensitive, but polarity matters if a suppression diode is used for access control applications.; MOV suppressor across the red and black power wires, to meet BHMA A156.31: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints red power wire to black power wire; when Installation configuration is Internal accessory connection; not field cable: Applies when the installer needs to meet BHMA A156.31. The supplied MOV is installed across the red and black power wires. This is a local component connection, not a new cable run.