CXPS13V3 – CX-PS13 V3: Variable Output Linear Power Supply

$60.00

CX-PS13 V3: Variable Output Linear Power Supply – Camden Door Controls

SKU: CXPS13V3
Category: ,
Brands:

Description

CX-PS13 V3: Variable Output Linear Power Supply – Camden Door Controls

Source: https://www.camdencontrols.com/products/CXPS13V3

Resources:
https://www.camdencontrols.com/pipelines/resource/12969_CX_PS13V3_Manual_R1.pdf
https://www.camdencontrols.com/pipelines/resource/12970_7DUO2V13KPQAPOFGT1XS.pdf

Reviews

There are no reviews yet.

Be the first to review “CXPS13V3 – CX-PS13 V3: Variable Output Linear Power Supply”

Your email address will not be published. Required fields are marked *

The CX-PS13 V3 is a power supply that accepts an external step-down AC transformer input and provides selectable regulated DC output voltage to a load, along with a gel cell battery backup output; it must not be connected directly to the 120 VAC line.

Product specifications
Output voltage options 6, 9, 12, 13.8, 18, or 24 VDC (jumper selectable)
Transformer input 6-26 VAC depending on selected output, 20-40 VA
Dimensions 2.70" (68.6mm) L x 1.50" (38.1mm) W x 1.750" (45.5mm) H
Low-voltage wiring Connection count needs review
PreparationAn input transformer is required and must be matched to the selected output voltage. The unit is mounted with the supplied adhesive tape. The mounting surface prerequisites are not documented.
ElectricalThe board takes AC input from a transformer and supplies DC output to a load. Both connections are physical. The manual's wiring diagram labels these as Input (From Transformer) and Output (To Load). Conductor counts and cable runs are not stated in the prose, and the diagram was not supplied visually.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsAC power input from an external transformer: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Transformer secondary to CX-PS13V3 AC input terminals; when Installation configuration is Base product. The transformer must match the selected output voltage and must not be the 120 VAC line.; DC output to the load: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints CX-PS13V3 DC output terminals to Load (e.g. electric strike); when Installation configuration is Base product. Used for electric strikes and other electrified devices.; Standby battery connection: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints CX-PS13V3 battery terminals B+/B- to Gell cell battery; when Installation configuration is Optional accessory selected: IF a gel cell backup battery is used. The manual says 12 in battery leads are provided, which are factory leads and not field cable.; AC input from the required transformer to the AC terminals: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Transformer to CX-PS13V3 AC input terminals; when Installation configuration is Base product. The input transformer is required and must match the selected output voltage. Cable run count and conductor count are not documented.; DC output to the load (for example an electric strike): cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints CX-PS13V3 DC output terminals to Load; when Installation configuration is Base product. Output voltage is set by the voltage selection jumpers (6, 12 or 24 VDC) or by ADJ with the voltage adjustment (2-24 VDC). Cable run count and conductor count are not documented.; Gel cell battery backup connection using the 12 in battery leads: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints CX-PS13V3 battery terminals (B-, B+) to Gel cell battery; when Installation configuration is Internal accessory connection; not field cable: Optional accessory selected: IF a gel cell battery is selected for backup. The battery is optional and not part of the base product. The 12 in battery leads are provided for this connection. The unit charges the battery and switches over automatically on AC failure.

Official manufacturer documents