Camden CX-PS600UL – 6A power supply, (8) fused outputs 2A, 12/24VDC, dual

$75.00

6A power supply, (8) fused outputs 2A, 12/24VDC, dual battery Variant record generated from manufacturer nomenclature (https://www.camdencontrols.com/products/CX_PS_Series); price inherited from product #3038 pending owner confirmation.

Brands:

Description

6A power supply, (8) fused outputs 2A, 12/24VDC, dual battery Variant record generated from manufacturer nomenclature (https://www.camdencontrols.com/products/CX_PS_Series); price inherited from product #3038 pending owner confirmation.

Reviews

There are no reviews yet.

Be the first to review “Camden CX-PS600UL – 6A power supply, (8) fused outputs 2A, 12/24VDC, dual”

Your email address will not be published. Required fields are marked *

Product specifications
Low-voltage wiring Connection count needs review
PreparationThe cabinet is mounted with its four mounting holes at an indoor, controlled-environment location. The AC mains input needs an accessible external disconnect with branch protection. The output voltage is selected with the SW1 jumper before use.
ElectricalAC input specification:120/240 VAC,50-60 Hz at2.5 A. DC output is6 A continuous at the selected12/24 VDC setting; the eight fused output channels do not each provide6 A. The battery charger maximum is1.5 A and the manual states this is separate from the maximum output-current rating. Select the actual voltage, connected loads, battery configuration, fire-alarm interface and monitoring functions before sizing circuits. AC-fail and battery-fail contacts are separately rated30 VDC,60 mA with16 ohms in the output table. These are monitoring contact ratings. Output-channel capacity and factory charging leads do not determine mandatory field cable runs.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsAC mains input (earth, neutral, live) to the AC input terminal block: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints 120-240 VAC mains via external disconnect to AC input terminal block; when Installation configuration is Base product, always required. Wire with correct phase and polarity: Ground = Green or Yellow, Neutral = Blue or White, Live = Black or Brown. The mains disconnect has a maximum 15 A branch protection.; DC power output to the powered devices: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Power supply output terminals Vo- / Vo+ to Powered devices; when Installation configuration is Base product, when powering devices directly from the output terminals. The output is 12 V or 24 V DC, selected by SW1.; Standby battery connection: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Power supply battery terminals to 12 V lead-acid battery or batteries; when Installation configuration is Internal accessory connection; not field cable: Base product, when standby batteries are used. Batteries are not included; the unit ships with battery charging leads. Connect only after AC is present, with correct polarity.; AC Fail and Battery Fail relay outputs to monitoring or panel trouble inputs: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints AC FAIL and BATTERY FAIL relay contacts to FACP/ACP or monitoring device; when Installation configuration is Base product, only if trouble monitoring is wanted. The contacts are normally closed and open on fault.; Fire alarm trigger, reset, and fused or relay outputs through the ACM8ECB distribution module: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints FACP/ACP fire trigger or reverse-polarity input to Reset key switch or push button to ACM8ECB output terminals to locks or strikes; when Installation configuration is Optional accessory selected: IF the ACM8ECB (or a similar ECB module) is selected. Two 2K2 EOL resistors are used with the module, and cascade wiring applies only for two or more modules. Wire counts are not given as a cable count in the supplied evidence.; Tamper switch: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Tamper switch TSW1-02 or TWS2-02 to Power supply tamper connector; when Installation configuration is Optional accessory selected: IF a tamper switch is required.