Description
Series: CX-ED2071/ED2079
Type: 'Universal' Low Profile Gr. 2 Electric Strike
Brand: Camden
Manufacturer Part Number: CX-ED2071
Source: Camden Controls product page
\’Universal\’ Low Profile Gr. 2 Electric Strike
Series: CX-ED2071/ED2079
Type: 'Universal' Low Profile Gr. 2 Electric Strike
Brand: Camden
Manufacturer Part Number: CX-ED2071
Source: Camden Controls product page
Camden CX-ED2071 and CX-ED2079 are low-profile, Grade 2 ANSI 'Universal' electric strikes for cylindrical locksets, offering field-selectable fail-safe/fail-secure operation and horizontal adjustability of the strike body. CX-ED2071 operates at 8-16V AC/DC and includes (3) stainless steel faceplates; CX-ED2079 operates at 12/24V AC/DC, is UL 1034 and UL 294 listed, and also includes (3) stainless steel faceplates (CX-ED2079-1 includes 1 faceplate).
| Voltage (CX-ED2071) | 8-16V AC/DC |
|---|---|
| Voltage (CX-ED2079) | 12/24V AC/DC |
| Current draw (CX-ED2071) | 305mA @ 8VDC, 625mA @ 16VDC, 190mA @ 8VAC, 460mA @ 16VAC |
| Current draw (CX-ED2079) | 300mA @ 12VDC, 150mA @ 24VDC |
| Static strength | 1,000 lbs |
| Dynamic strength | 50 ft-lbs |
| Mode | field selectable fail safe/fail secure |
| Operation | AC – Buzz, DC – Silent |
| Mounting | non-handed |
| Duty (CX-ED2071) | intermittent |
| Duty (CX-ED2079) | continuous |
| Endurance (CX-ED2071) | 700,000 cycles (factory tested), 250,000 cycles (UL verified) |
| Endurance (CX-ED2079) | 700,000 cycles (factory tested), 500,000 cycles (UL verified) |
| Dimensions | 4-7/8" H x 1-7/8" W x 1-7/32" D (124mm x 47mm x 31mm) |
| Latch projection | 1/2" – 5/8" (13mm – 16mm) |
| Listing | UL 1034, UL 294 |
| Warranty | 5 year warranty |
| Certification | ANSI/BHMA A156.31, Grade 1 certified (CX-ED2079 Series) |
| Low-voltage wiring | Required |
| Basis | Structured, independently qualified product connection evidence |
| Electrical | The strike has two red power leads. These are spliced to the supplied wire, with the supplied varistor connected between the two input wires. Power is 8/16V AC/DC from a Class 2 power-limited, UL-listed supply or control panel. No separate control or signal wires are documented. The cable run count and field cable gauge are not stated. |
| Preparation required | Yes |
| Electrical wiring required | Yes |
| Conditional connections | Strike power input, 8/16V AC/DC, from a Class 2 supply or control panel: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints strike red power leads to Class 2 power supply or control panel; when Installation configuration is Base product. The two red strike leads are spliced to the supplied wire and connected to the supply. The number of field cable runs and conductors is not documented, so both stay unknown.; Varistor surge protection across the two power input wires: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints varistor to the two red power input wires; when Installation configuration is Supplied varistor is connected between the two input wires. The instructions say the connection varies with input voltage, but the table shows red to red for 8V/16V AC/DC. It is a local component, not a separate cable run. |