Camden CX-DE1200-N4 – Delayed egress mag lock, single door, 15s fixed

Delayed egress mag lock, single door, 15s fixed, NFPA/IBC/IFC/UBC Variant record generated from manufacturer nomenclature (https://www.camdencontrols.com/products/DE1200); price inherited from product #3450 pending owner confirmation.

SKU: CX-DE1200-N4
Category: , ,
Brands:

Description

Delayed egress mag lock, single door, 15s fixed, NFPA/IBC/IFC/UBC Variant record generated from manufacturer nomenclature (https://www.camdencontrols.com/products/DE1200); price inherited from product #3450 pending owner confirmation.

Reviews

There are no reviews yet.

Be the first to review “Camden CX-DE1200-N4 – Delayed egress mag lock, single door, 15s fixed”

Your email address will not be published. Required fields are marked *

Product specifications
Low-voltage wiring Required
BasisStructured, independently qualified product connection evidence
PreparationFor an indoor outward-swing door, use the supplied door/frame template to drill mounting holes and the 1/2-inch cable access hole. Fit the mounting plate to the frame and armature housing to the door; route wiring through the frame and mounting plate into the lock.
ElectricalProvide auto-sensing 12/24 VDC +/-10% power from a UL 294 or UL 603 listed Class 2 power-limited supply; listed draw is 600mA / 350mA respectively. Observe DC input polarity, limit all field wiring to 30m (98.5ft), and integrate the fire alarm so fire bypasses the exit delay. R-Exit, Reset and Ex-Trig require normally open momentary dry contacts; do not apply voltage to these inputs.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsScoped installation connections for CX-DE1200-N4: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating Use the selected manufacturer configuration. Numeric field counts and cable-run quantities remain unknown unless separately stated.; endpoints CX-DE1200-N4 documented terminals or leads to Selected external power and control circuits; when Installation configuration is Connect supply to PWR +/-. Fire P is the supervised normally closed fire-alarm input; remove J10 only when the NC dry contact from fire alarm/smoke detection is connected. External trigger, request-to-exit, reset, bypass, external speaker, lock/alarm/status outputs and monitoring circuits depend on installed accessories and controls. Do not use the Lock output in the single-door configuration. Keep accessory circuits and external field conductors distinct; see original terminal diagram for selected circuits.