Camden CM-45/454SE1 – 4-1/2″ Push Plate Switch, Wheelchair & Push to Open, with Surface AURA™ Illuminated Enclosure and Sign

$50.00

4-1/2\” Push Plate Switch, Wheelchair & Push to Open, with Surface AURA(tm) Illuminated Enclosure and Sign

SKU: CM-45/454SE1
Category: ,
Brands:

Description

Series: CX-WC Series

Type: Barrier Free Restroom Control

Configuration: Barrier Free Components – Combined Activation & Annunciation

4-1/2\” Push Plate Switch, Wheelchair & Push to Open, with Surface AURA(tm) Illuminated Enclosure and Sign

Brand: Camden

Manufacturer Part Number: CM-45/454SE1

Source: Camden Controls product page

Additional information

graphic

/1 blank, /2 wheelchair blue, /2AL wheelchair+arrow left, /2AR wheelchair+arrow right, /3 push to open black, /3F poussez pour ouvrir blac, /4 wheelchair+push to open, /4AL wheelchair+arrow left bl, /4AR wheelchair+arrow right b, /4F wheelchair+french black, /8 push to lock black, /8B lock symbol+push to lock, /8D push to lock door black, /8F poussez pour verrouiller

Reviews

There are no reviews yet.

Be the first to review “Camden CM-45/454SE1 – 4-1/2″ Push Plate Switch, Wheelchair & Push to Open, with Surface AURA™ Illuminated Enclosure and Sign”

Your email address will not be published. Required fields are marked *

Product specifications
Low-voltage wiring Connection count needs review
PreparationPosition the white vinyl behind the surface Aura enclosure, then fix the enclosure to the wall using the supplied pan-head screws and green PVC anchors appropriate to the substrate. Align the Aura board with the enclosure holes and secure with #6 x 3/8 inch self-tapping screws. Fit the Aura insert with mounting holes aligned. Partially fit the 6-32 hex screws, locate the assembled push plate over them, then tighten through its faceplate access holes. Fit the sign/label to its supplied vinyl backing. Follow the component installation instructions alongside the WC13 drawing; confirm actual template and delivered assembly before cutting.
ElectricalIn the documented WC13/CX-33 configuration, the Aura power input takes 12 or 24 V AC/DC through a two-conductor external supply connection; its power terminals are not polarity sensitive. The Aura REM pair connects to CX-33 relay 3 COM/NO, with consistent polarity between paralleled Aura remote inputs. The local exterior Push to Open contact connects to Aura PBTN; Aura COM/NO then connects by two external conductors to CX-33 DRY1 and its input return. The local PBTN loop is not an additional external cable run. These are conditional circuit conductor counts, not cable-jacket quantities. Confirm actual board current/contact ratings, controller mode and field cable type/gauge/routing before installation. Do not infer controller mode solely from the faceplate graphic.
Conditional connectionsCM-45/454SE1 WC13 Aura power pair: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type/gauge, routing and physical jacket/run quantity unspecified.; endpoints External 12/24 V AC/DC supply to Aura power terminals; when Installation configuration is Only the documented WC13/CX-33 wired application; select exact system mode and actual assembly. Internal PBTN loop excluded.; CM-45/454SE1 WC13 remote colour pair: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type/gauge, routing and physical jacket/run quantity unspecified.; endpoints CX-33 relay3 COM and NO to Aura REM pair; when Installation configuration is Only the documented WC13/CX-33 wired application; select exact system mode and actual assembly. Internal PBTN loop excluded.; CM-45/454SE1 WC13 Aura activation relay pair: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type/gauge, routing and physical jacket/run quantity unspecified.; endpoints Aura COM and NO to CX-33 DRY1 and input return; when Installation configuration is Only the documented WC13/CX-33 wired application; select exact system mode and actual assembly. Internal PBTN loop excluded.