Description
Series: CM-4000/4100
Type: 1-5/8" Pushbutton, Aluminum Faceplate
Configuration: Single Gang Faceplate
Spring Return, DPST 1-60 sec Pneumatic Timer (ADA)
Brand: Camden
Manufacturer Part Number: CM-4085
Source: Camden Controls product page
Spring Return, DPST 1-60 sec Pneumatic Timer (ADA)
Series: CM-4000/4100
Type: 1-5/8" Pushbutton, Aluminum Faceplate
Configuration: Single Gang Faceplate
Spring Return, DPST 1-60 sec Pneumatic Timer (ADA)
Brand: Camden
Manufacturer Part Number: CM-4085
Source: Camden Controls product page
Camden Door Controls 4000/4100 Series of push switches are heavy duty pushbuttons, specially designed and manufactured to meet the stringent demands of exit controls. Buttons are available in either green, red, or blue, 1 5/8” diameter. They are supplied with a 1/4” thick brushed aluminum plate in 1 3/4” or 2 3/4” widths.
| Low-voltage wiring | Required |
|---|---|
| Basis | Structured, independently qualified product connection evidence |
| Preparation | Provide a compatible single-gang mounting arrangement and verify clearance for the complete unit, documented as 114mm high x 70mm wide x 54mm deep. The manual lists CM-66 flush box/dress plate, CM-31 surface-box sleeve and CM-34D extra-depth surface box as options; select the actual mounting arrangement for the site. Set the pneumatic delay with its thumbscrew within the documented 1-60 second range. The modular assembly uses a bayonet interlock and needs no set screws. Do not use the replacement faceplate component dimension as the complete button body depth. |
| Electrical | Low-voltage field wiring is required for the selected switching circuit. Use the white lead pair for normally open operation or the red lead pair for normally closed operation: two external conductors for each selected pole. If both independent poles are used, four separate circuit conductors are needed; the schematic shows no shared common. The two white and two red factory tails are not field cable runs. The pneumatic timer requires no electrical supply. Select field cable type, gauge, shielding and physical run quantities for the actual connected equipment and site; these are unspecified in the manufacturer manual. |
| Preparation required | Yes |
| Electrical wiring required | Yes |
| Conditional connections | Selected normally open pneumatic-switch circuit: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Select field cable type, gauge, shielding and run quantity for connected equipment and site; unspecified by manufacturer.; endpoints Selected low-voltage controlled equipment to CM-4085 white contact lead pair; when Installation configuration is If the normally open pole is selected, use its two white leads. This pole is independent of the other pole; wire both pairs separately if both functions are used.; Selected normally closed pneumatic-switch circuit: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Select field cable type, gauge, shielding and run quantity for connected equipment and site; unspecified by manufacturer.; endpoints Selected low-voltage controlled equipment to CM-4085 red contact lead pair; when Installation configuration is If the normally closed pole is selected, use its two red leads. This pole is independent of the other pole; wire both pairs separately if both functions are used. |