Camden CM-221/A42W – ValueWave™ Touchless Switch, Double Gang,

$50.00

ValueWave™ Touchless Switch, Double Gang,

SKU: CM-221/A42W
Category:
Brands:

Description

Series: CM-221 & CM-222 Series

Type: ValueWave™ Touchless Switches

Configuration: Wave To Open

ValueWave™ Touchless Switch, Double Gang,

Brand: Camden

Manufacturer Part Number: CM-221/A42W

Source: Camden Controls product page

Additional information

graphic

/40 hand icon, /41 hand icon + wave to open, /42 hand icon+wave to open+w, /43 hand icon + wave to lock, /44 hand icon + wheelchair, /46 hand icon + wave to exit, /A42 hand icon + active wheel, /A44 hand icon+wave to open+a

Reviews

There are no reviews yet.

Be the first to review “Camden CM-221/A42W – ValueWave™ Touchless Switch, Double Gang,”

Your email address will not be published. Required fields are marked *

Camden's CM-221 and CM-222 Series ValueWave touchless switches provide hands-free activation to reduce germ spread, offering industry-leading reliability and performance. Ideal for indoor or outdoor use as part of an automatic door or access control system, they are designed for easy installation and trouble-free service in high-traffic applications.

Product specifications
Operating voltage 12-24 VDC +/- 10%
Power requirement filtered and regulated DC power supply required
Current draw 45 mA (peak)
Contact rating 1 amp @ 30VDC
Contacts (1) Form C contact, common/N.O./N.C.
Response time 10 ms
Temperature range 14°F to 122°F (-10°C to +50°C)
Sensor range 2" to 8" (5 to 20cm), adjustable
Time delay 0.5 to 20 seconds, adjustable, with toggle operation
IP rating IP 65
Faceplate heavy gauge stainless steel
Low-voltage wiring Required
BasisStructured, independently qualified product connection evidence
PreparationProvide the compatible double-gang mounting arrangement; the manufacturer lists the CM-53 double-gang surface box. Prepare access for the low-voltage power and controlled-device wiring. Before connecting the switch, measure the supply and use filtered, regulated DC; never apply AC directly to this sensor.
ElectricalRequires 12 to 24 VDC (+/-10%); DC only. For the illustrated door-operator connection, connect the operator trigger pair to blue COMMON and green N/O, with black to supply negative and red to supply positive. White and yellow are additional remote LED-control connections when external LED mode is selected. Purple is the N/C relay alternative for the applicable lock circuit. Isolate unused conductors individually. The upstream transformer shown in the diagram does not make the sensor an AC device.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsDoor-operator normally open trigger interface: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field-cable gauge, shielding and physical cable-jacket quantity are not specified by this manual.; endpoints CM-221/A42W blue COMMON and green N/O to Door operator trigger input; when Installation configuration is CM-221/A42W without mechanical override: selected door-operator application, using separate DC supply. Optional remote LED control and N/C lock circuits are separate. This interface count does not establish physical cable runs.; DC power interface: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field-cable gauge, shielding and physical cable-jacket quantity are not specified by this manual.; endpoints CM-221/A42W red positive and black negative to External 12 to 24 VDC power supply; when Installation configuration is CM-221/A42W without mechanical override: selected door-operator application, using separate DC supply. Optional remote LED control and N/C lock circuits are separate. This interface count does not establish physical cable runs.