LCN 9563 Operator

$450.00

Variant record created for schedule matching; price inherited from product #1233 pending owner confirmation.

SKU: 9563
Category:
Brands:

Description

Variant record created for schedule matching; price inherited from product #1233 pending owner confirmation.

Additional information

handing

LH, Non-handed, RH

finish

628, 710, 711

voltage

115V, 230V

arm

LNGTLS2, LONG2, REG/STD, REG2, STDTRACKARM2, TLS/STD, TLS2

Reviews

There are no reviews yet.

Be the first to review “LCN 9563 Operator”

Your email address will not be published. Required fields are marked *

Product specifications
Low-voltage wiring Connection count needs review
PreparationCheck the approved opening drawings and header clearances. Prepare header wire-access holes for the selected surface installation using template 740070. For mounting onto a 2-inch frame, consult the manufacturer to determine whether a mounting plate is required.
ElectricalFor the documented 120 VAC configuration, provide a dedicated single-phase 60 Hz supply fused at 15 A at the side jamb, with approximately 12 inches of wire available to connect the operator. The manufacturer specifies a 3-wire supply and recommends UL-approved flexible conduit. The legacy model reference also lists an optional 240 V configuration; these 120 V instructions do not establish its wiring requirements. Accessory activation, safety and locking connections depend on the selected devices.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connections120 VAC field power supply at side jamb to operator: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Dedicated mains circuit at side jamb to Operator AC supply connection and header earth; when Installation configuration is IF the legacy operator is configured for the 120 VAC supply covered by manual 740132. Three field supply conductors per connection; this is not a total cable-run count. Optional 240 V configurations and accessory circuits are not established by this count.; Selected activation, safety and locking accessory circuits: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Senior Swing control box to Selected activation, safety or locking device; when Installation configuration is Optional accessory selected: IF an activation, safety or locking accessory is selected, follow its own instructions. Conductor counts and cable-run quantities remain unknown here.; 120 V AC supply to the operator (power only, separate from control wiring): cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints 120 V dedicated branch circuit at side jamb to operator in header; when Installation configuration is Senior Swing surface and concealed installations per the generic instructions (applicability to 9563 inferred from the Senior Swing family only). The 3-wire supply (line, neutral, ground per instruction text) is fed through conduit into the header, with at least 12 inches of wire left in the header for final hookup. 115 V is the 9563 default voltage and 240 V is an option; the instructions cover the 120 V case only. Cable run count and conductor gauge are not documented. The page 5 figure 2-3 shows conduit and wire entering the jamb and header, but the number of cable runs is not determinable.