Camden CX-ED1410-BK – ‘Universal’ Grade 1 ANSI Fire Rated Electric Strike, with an all-black finish faceplate

$50.00

‘Universal\’ Grade 1 ANSI Fire Rated Electric Strike, with an all-black finish faceplate

SKU: CX-ED1410-BK
Category:
Brands:

Description

Series: CX-ED1410 & CX-ED1420 Series

Type: 'Universal' Grade1 ANSI Fire-Rated Electric Strikes

‘Universal' Grade 1 ANSI Fire Rated Electric Strike, with an all-black finish faceplate

Brand: Camden

Manufacturer Part Number: CX-ED1410-BK

Source: Camden Controls product page

Reviews

There are no reviews yet.

Be the first to review “Camden CX-ED1410-BK – ‘Universal’ Grade 1 ANSI Fire Rated Electric Strike, with an all-black finish faceplate”

Your email address will not be published. Required fields are marked *

The CX-ED1410 (standard depth, 5/8"-3/4" latch projection) and CX-ED1420 (low profile, 1/2"-5/8" latch projection) are UL 1034/UL 294 and UL 90-minute fire rated, ANSI/BHMA A156.31 Grade 1 electric strikes for cylindrical locksets. They offer dual 12/24V AC/DC voltage and field-selectable fail-safe/fail-secure operation, with an ANSI square faceplate and trim plate included.

Product specifications
Voltage 12/24V AC/DC
Current draw 260mA @ 12V AC/DC
Static hold force 1,500 Lbs.
Fire rating 90 Minutes (UL Verified)
Operation Field selectable fail safe / fail secure (Fire rated in fail secure mode only)
Duty Continuous
Latch projection CX-ED1410: 5/8"-3/4" (16mm-19mm); CX-ED1420: 1/2"-5/8" (12mm-16mm)
Dimensions CX-ED1410: 3-3/8" L x 1-7/8" W x 1-3/8" D (86mm x 47mm x 35mm); CX-ED1420: 3-3/8" L x 1-7/8" W x 1-3/16" D (86mm x 47mm x 31mm)
Low-voltage wiring Required
BasisStructured, independently qualified product connection evidence
PreparationUse the standard-depth CX-ED1410-BK with the actual compatible cylindrical latch and its matching template. Use the purchased black-finish ANSI square faceplate. Align the strike to the latch and prepare the required mortise using the model-specific depth/template. Fit the supplied brackets in hollow metal, test-fit before tightening, or verify the existing ANSI cutout before fastening. Follow the wood-frame fastener instructions when applicable. Preserve emergency-exit hardware operation. The strike ships fail-secure; change mode only by loosening the mode screw, rotating and seating the set plate, then retightening. The manual limits the fire rating to fail-secure operation; verify the actual opening requirements before selecting a mode.
ElectricalChoose the supplied harness for the actual 12/24V AC/DC supply. Its two external supply conductors are separate from four factory coil tails. For the documented DC cut-wire option, 12V uses red/black positive and blue/green negative; 24V uses red positive, green negative and black/blue joined locally. Connect the supplied varistor across the input pair as drawn. The generic mounting text mentions a black wire; use the voltage-specific connection diagram and actual harness identification rather than assigning a universal black-wire polarity. DC polarity does not apply to AC supply. Use the documented Class 2 power-limited output for the listed application. Current draw is 260mA at 12V DC or 150mA at 24V DC; AC operation buzzes and DC is silent. Cable-run quantity, type, gauge and shielding remain installation-specific and are not established by the coil-tail count.
Electrical wiring requiredYes
Conditional connectionsCX-ED1410-BK selected voltage-harness supply: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical cable-run quantities unspecified; factory tails and local joins separate.; endpoints Compatible selected12/24VAC/DC external supply to Matching supplied12V or24V strike harness; when Installation configuration is Select the supplied harness matching actual voltage; its two field connections are distinct from four internal coil tails. AC/DC choice follows supplied product rating.; CX-ED1410-BK 12VDC cut-wire power alternative: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical cable-run quantities unspecified; factory tails and local joins separate.; endpoints Compatible external 12VDC supply to Red/black positive and blue/green negative; when Installation configuration is Only when the documented cut-wire 12VDC configuration is used instead of the voltage harness; varistor across supply, local coil joins separate. Alternatives are not additive.; CX-ED1410-BK 24VDC cut-wire power alternative: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical cable-run quantities unspecified; factory tails and local joins separate.; endpoints Compatible external 24VDC supply to Red positive and green negative; black/blue local join; when Installation configuration is Only when the documented cut-wire 24VDC configuration is used instead of the voltage harness; varistor across supply, local coil joins separate. Alternatives are not additive.