Description
Series: CM-331/332/333/336/324/325 Series
Type: SureWave™ Touchless Switches
Configuration: Touchless Switch, 1 Relay
Wired
Brand: Camden
Manufacturer Part Number: CM-325
Source: Camden Controls product page
Series: CM-331/332/333/336/324/325 Series
Type: SureWave™ Touchless Switches
Configuration: Touchless Switch, 1 Relay
Wired
Brand: Camden
Manufacturer Part Number: CM-325
Source: Camden Controls product page
| graphic | /40 hand icon, /41 hand icon+wave to open, /42 hand icon+wave to open+w, /43 hand icon+wave to lock, /44 hand icon+wheelchair |
|---|
Camden's SureWave touchless switches (CM-324, CM-325, and related CM-331/332/333/336 models) are hands-free door activation switches with adjustable operating range (1-30") and adjustable time delay (1-5 seconds), designed for economical door activation while reducing the spread of germs. CM-324 is line-powered with 1 relay for general use; CM-325 offers short-range sensing suited to confined areas such as restrooms.
| Operating voltage | 12-24 Volts, AC/DC ± 12% |
|---|---|
| Current draw | 50 – 60 mA |
| Response time | 100 ms |
| Contact rating | 5 Amps @ 30 VDC |
| Switch life | 100,000 Operations @ Rated Capacity; 500,000 Operations @ 1/2 Rated Capacity |
| Temperature | -4°F to +185°F (-20°C to +85°C) |
| Output type | Normal or Fail-Safe, Form 'C' (SPDT) |
| Time delay | 1 to 5 seconds |
| Low-voltage wiring | Connection count needs review |
| Preparation | For the base single-gang CM-325, use an in-wall box that is plumb, square and flush with the wall, or a surface box that is secure and plumb. The supplied sealing gasket is recommended for outdoor or wet locations. Bring the specified four-conductor basic field connection through the rear or side and leave approximately 6 inches for connection. Finish wiring and mode settings before applying power. Secure with supplied screws, adjust range and time delay, then fit the faceplate without overtightening. |
| Electrical | Supply 12 or 24 V AC/DC to the two red non-polarity-sensitive power leads. Blue is relay NO, green COM and violet NC. For the selected normal low-voltage output use blue/green; for the documented fail-safe selection use green/violet with the specified mode setting. Each selected output pair needs two external conductors, separate from the two-conductor supply circuit; do not add both alternative output pairs together. The manual basic installation calls for four conductors. Its 11-inch 22 AWG leads are factory pigtails and do not specify field cable gauge. Current is 50-60 mA and relay contact rating is 5 A at 30 VDC. Choose field cable gauge/type, route and physical run quantity for the installation. |
| Preparation required | Yes |
| Conditional connections | CM-325 power input: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable gauge/type/shielding, routing and physical run quantity unspecified.; endpoints External 12/24 V AC/DC supply to Two red power leads; when Installation configuration is Base power, non-polarized.; CM-325 normal NO output: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable gauge/type/shielding, routing and physical run quantity unspecified.; endpoints Blue NO and green COM to External low-voltage controlled input; when Installation configuration is Normal mode only; alternative to NC output.; CM-325 alternative NC output: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable gauge/type/shielding, routing and physical run quantity unspecified.; endpoints Violet NC and green COM to External low-voltage controlled input; when Installation configuration is Only documented fail-safe mode selection; alternative to normal NO output. |