Description
Series: CM-3000/3100 Series
Type: Illuminated Mushroom Pushbutton
Configuration: Single Gang Faceplate
Push/Pull Button, N/O, Maintained
Brand: Camden
Manufacturer Part Number: CM-3030
Source: Camden Controls product page
Series: CM-3000/3100 Series
Type: Illuminated Mushroom Pushbutton
Configuration: Single Gang Faceplate
Push/Pull Button, N/O, Maintained
Brand: Camden
Manufacturer Part Number: CM-3030
Source: Camden Controls product page
Camden Door Controls CM-3000/3100 Series Exit Switches are heavy duty push-buttons designed for industrial and commercial applications where illumination is required. Buttons are 1 5/8" (40mm) in diameter, available in red or green, with a 1/4" thick brushed aluminum faceplate in 1 3/4" or 2 3/4" widths. The switches are UL/CSA approved, rated 10 amps @ 30V DC, for either momentary or maintained operation.
| Low-voltage wiring | Required |
|---|---|
| Basis | Structured, independently qualified product connection evidence |
| Preparation | The supplied evidence gives product dimensions and says the switch can be surface, flush or mullion mounted. It does not give a mounting box depth, cutout size or prepared-surface requirement for CM-3030. The installation manual was not supplied. |
| Electrical | CM-3030 uses a N/O SPST contact block with maintained push/pull action. For a selected direct 12/24 VDC control circuit, connect the two-conductor switching loop to common and normally open. The LED supply is separate: connect two supply conductors at X1/X2 directly for 12 VDC; for 24 VDC put the supplied resistor in series with either X1 or X2. These interface counts do not state how many cable jackets/runs to pull. Field wire type and gauge are not specified by this manual; factory lead sizes are not field cable requirements. |
| Preparation required | Yes |
| Electrical wiring required | Yes |
| Conditional connections | Separate LED low-voltage supply at X1/X2: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field wire type, conductor size, shielding and physical run quantity are not specified by this manufacturer manual. Select for the actual low-voltage system and site.; endpoints External selected12/24VDC supply to LED terminals X1 and X2; when Installation configuration is Selected direct12VDC supply:connect X1/X2 directly. Selected24VDC supply:insert the supplied resistor in series with either X1 or X2. This is the external LED supply pair, separate from the switch loop; physical cable runs are unknown.; N/O SPST low-voltage controlled contact circuit: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field wire type, conductor size, shielding and physical run quantity are not specified by this manufacturer manual. Select for the actual low-voltage system and site.; endpoints CM-3030 N/O SPST contact block to Selected external12/24VDC controlled circuit; when Installation configuration is Selected12/24VDC control circuit with maintained push/pull operation. Use common and normally open as the two external points of this selected direct switching loop. Factory tails, unused terminals and LED supply are excluded from this interface count. Physical cable runs remain unknown. |
Reviews