Camden CM-1150 – Key Switch (2) SPDT Momentary

$75.00

Key Switch (2) SPDT Momentary

SKU: CM-1150
Category:
Brands:

Description

Series: CM-1100 & CM-2000 Series

Type: Cast Aluminum, Flush Mount

Configuration: Single Gang Faceplate

Key Switch (2) SPDT Momentary

Brand: Camden

Manufacturer Part Number: CM-1150

Source: Camden Controls product page

Reviews

There are no reviews yet.

Be the first to review “Camden CM-1150 – Key Switch (2) SPDT Momentary”

Your email address will not be published. Required fields are marked *

Camden Door Controls, CM-1100 and CM-2000 Series flush mount key switches meet the stringent demands of key switch controls. They are designed for use with standard 1”, 1 1/8”, or 1 1/4” mortise cylinders. Fabricated from 1/4” thick aluminum, into a one piece die cast construction, with unique Camden Manufacturing features.

Product specifications
Low-voltage wiring Required
BasisStructured, independently qualified product connection evidence
PreparationThe CM-1150 is a single-gang flush-mount key switch. It needs a mortise cylinder and a compatible mounting box or surface prepared for a 4-1/2" x 2-3/4" faceplate. The cylinder is listed as sold separately in the optional cylinder table. Whether one is included with the CM-1150 is not confirmed.
ElectricalBase configuration: Key Switch (2) SPDT Momentary. For each used changeover pole, common plus NO or common plus NC requires two external conductors; common plus both NO and NC requires three. Apply that choice separately to each of the two supplied switches. Do not join independent commons by assumption. These are low-voltage circuit conductor counts, not physical cable-run counts. The supplied 18 AWG soldered leads do not specify field cable gauge. Common is grey; momentary NO is blue and NC orange. The maintained-contact chart lists both throw leads orange, so identify the actual terminal function before connecting. Cable type, gauge, shielding and physical run quantities depend on the selected controller/device and site routing. Optional LED circuits remain separate and require their selected DC option instructions. The standard-contact parts table and family specification give different contact ratings; verify the fitted switch rating. Contact ratings are not supply requirements.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsOptional LED power circuit: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints optional LED leads to 12 VDC or 24 VDC supply; when Installation configuration is Optional accessory selected: IF an optional LED variant is selected (key switches may be ordered with LEDs). The LEDs are DC only. This is not part of the base CM-1150.; Selected base switch 1: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1150 switch 1 common and NO; when Installation configuration is For switch 1, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1150 switch 1 common and NC; when Installation configuration is For switch 1, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1150 switch 1 common, NO and NC; when Installation configuration is For switch 1, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1150 switch 2 common and NO; when Installation configuration is For switch 2, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1150 switch 2 common and NC; when Installation configuration is For switch 2, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1150 switch 2 common, NO and NC; when Installation configuration is For switch 2, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.

Official manufacturer documents