Camden CM-1092 – Surface Mount Key Switch, (2) DPDT Maintained

$75.00

Surface Mount Key Switch, (2) DPDT Maintained

SKU: CM-1092
Category:
Brands:

Description

Series: CM-1000 Series

Type: Cast Aluminum with Surface Box

Surface Mount Key Switch, (2) DPDT Maintained

Brand: Camden

Manufacturer Part Number: CM-1092

Source: Camden Controls product page

Reviews

There are no reviews yet.

Be the first to review “Camden CM-1092 – Surface Mount Key Switch, (2) DPDT Maintained”

Your email address will not be published. Required fields are marked *

Camden Door Controls, CM-1000 Series surface mount switches meet the stringent demands of key switch controls. They are designed for use with standard 1", 1 1/8", or 1 1/4" mortise cylinders, fabricated from 1/4" thick aluminum into a one-piece die-cast construction. All controls provide for one (1) or two (2) switch configurations.

Product specifications
Low-voltage wiring Required
BasisStructured, independently qualified product connection evidence
PreparationThe key switch is supplied with a surface box, faceplate, gasket, lock ring and screws. The mortise cylinder is not included and must be sourced separately; it must be 1 inch to 1-1/4 inch. The box is 4-1/2 x 2-3/4 x 2 inches and has a threaded 1/2 inch conduit entry. A prepared surface, wall, pipe or pedestal is needed for surface mounting.
ElectricalBase configuration: Surface Mount Key Switch, (2) DPDT Maintained. For each used changeover pole, common plus NO or common plus NC requires two external conductors; common plus both NO and NC requires three. Each DPDT switch contains two independent poles. Apply that choice separately to each of the two supplied switches. Do not join independent commons by assumption. These are low-voltage circuit conductor counts, not physical cable-run counts. The supplied 18 AWG soldered leads do not specify field cable gauge. Common is grey; momentary NO is blue and NC orange. The maintained-contact chart lists both throw leads orange, so identify the actual terminal function before connecting. Cable type, gauge, shielding and physical run quantities depend on the selected controller/device and site routing. Optional LED circuits remain separate and require their selected DC option instructions. The standard-contact parts table and family specification give different contact ratings; verify the fitted switch rating. Contact ratings are not supply requirements.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsSelected base switch 1 pole 1: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1092 switch 1 pole 1 common and NO; when Installation configuration is For switch 1 pole 1, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1 pole 1: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1092 switch 1 pole 1 common and NC; when Installation configuration is For switch 1 pole 1, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1 pole 1: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1092 switch 1 pole 1 common, NO and NC; when Installation configuration is For switch 1 pole 1, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1 pole 2: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1092 switch 1 pole 2 common and NO; when Installation configuration is For switch 1 pole 2, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1 pole 2: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1092 switch 1 pole 2 common and NC; when Installation configuration is For switch 1 pole 2, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1 pole 2: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1092 switch 1 pole 2 common, NO and NC; when Installation configuration is For switch 1 pole 2, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2 pole 1: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1092 switch 2 pole 1 common and NO; when Installation configuration is For switch 2 pole 1, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2 pole 1: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1092 switch 2 pole 1 common and NC; when Installation configuration is For switch 2 pole 1, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2 pole 1: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1092 switch 2 pole 1 common, NO and NC; when Installation configuration is For switch 2 pole 1, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2 pole 2: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1092 switch 2 pole 2 common and NO; when Installation configuration is For switch 2 pole 2, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2 pole 2: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1092 switch 2 pole 2 common and NC; when Installation configuration is For switch 2 pole 2, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2 pole 2: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1092 switch 2 pole 2 common, NO and NC; when Installation configuration is For switch 2 pole 2, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.

Official manufacturer documents