Description
Same as the 8310-856, with the
added engraving of “Push to
Open”
Same as the 8310-856, with the
added engraving of “Push to
Open”
| Brand | LCN |
|---|
LCN 8310 Series is a modular system of touchless and push-plate door actuators, wireless transmitter/receiver sets, mounting boxes, escutcheons, weather/trim rings, safety sensors, and accessory kits used to remotely actuate LCN automatic swing-door operators (e.g., 4630/4640, 7900 pneumatic auto-equalizer, 9100 Benchmark, Senior Swing 2800/9500, Mid Swing 2900/9700 series). Touchless actuators and hardwired push plates require a wired, low-voltage power/control connection back to the door operator control box; most are also compatible with a 433 MHz or 900 MHz wireless transmitter/receiver pair for wireless actuation signaling instead of a run of activation wire. A subset of push plates (8310-852WP/853WP) are fully wireless/battery powered with no field control wiring at the plate itself (only the receiver, sold separately, is wired to the operator).
| Touchless actuator supply (8310-813) | 12-24 VAC ±10% or 12-24 VDC +30%/-10%, SELV-compatible power supplies only; power consumption < 1.5W; output is a voltage-free relay (max 60VDC/125VAC, 1A resistive, 30W) |
|---|---|
| 900 MHz receiver input voltage (8310-880) | 12-24 VAC/VDC; relay contact rating 1.0A@30VDC, 0.3A@60VDC, 0.5A@125VAC |
| Wireless transmitter power consumption (900 MHz) | 30mA (standard TX) / 40mA (RX) / 22mA (retrofit TX) |
| Receiver capacity | up to 74-75 transmitters per standard receiver; unlimited for 'universal' mode |
| Low-voltage wiring | Required |
| Basis | Structured, independently qualified product connection evidence |
| Preparation | Prepare the compatible electrical mounting box. Fit any selected adapter plate, bracket or weather ring before securing the push plate. Align the plate holes with the enclosure screws, slide the plate down, tighten it securely and test activation. |
| Electrical | Connect the bare push plate using its NO and COM dry contacts to the selected door controller or radio-controlled transmitter. Follow the selected operator circuit; receiver supply wiring is a separate interface. The switch contact is not an instruction to connect the plate to operator mains power. |
| Preparation required | Yes |
| Electrical wiring required | Yes |
| Conditional connections | Hardwired push-plate activation interface: cable runs quantity unspecified; 2 conductor(s); wire type Copper conductors; Class2 control circuit. Gauge and shielding not specified.; size unspecified; shielding unspecified; rating Wire type: copper conductors for the selected Class2 low-voltage control circuit. Keep this wiring separate from Class1 mains wiring. The cited manufacturer instructions do not specify conductor gauge or shielding. Runs: determine physical cable-jacket quantity from the actual route and parallel-actuator topology; the two-conductor interface count is not a cable-run count. Apply the actual operator and circuit revision. The count is at the selected activation interface; mains/safety/receiver circuits are separate.; endpoints Bare push plate NO and COM dry contacts to External LCN4630/4640 single-door activation circuit shown in manufacturer diagram; when Installation configuration is Only the hardwired4630/4640 single-door circuit illustrated on original manual page4. Two field conductors connect this standard push plate to the activation circuit. Interior and exterior contacts are parallel in that example. Excludes local transmitter connections, receiver power, other operator circuits and cable-run/new-pull quantities; no whole-installation total is implied. |