LCN 8310-868F – Flush Mount Box

$25.00

Model 8310-868F. Installer-grade flush mount box.

SKU: 8310-868F
Category:
Tags: , ,
Brands:

Description

Rugged Plastic Box, 4-1/2˝
Round
Optional accessory – can be used
w/any 4-1/2˝ round actuator

Additional information

Brand

LCN

Reviews

There are no reviews yet.

Be the first to review “LCN 8310-868F – Flush Mount Box”

Your email address will not be published. Required fields are marked *

LCN 8310 Series is a modular system of touchless and push-plate door actuators, wireless transmitter/receiver sets, mounting boxes, escutcheons, weather/trim rings, safety sensors, and accessory kits used to remotely actuate LCN automatic swing-door operators (e.g., 4630/4640, 7900 pneumatic auto-equalizer, 9100 Benchmark, Senior Swing 2800/9500, Mid Swing 2900/9700 series). Touchless actuators and hardwired push plates require a wired, low-voltage power/control connection back to the door operator control box; most are also compatible with a 433 MHz or 900 MHz wireless transmitter/receiver pair for wireless actuation signaling instead of a run of activation wire. A subset of push plates (8310-852WP/853WP) are fully wireless/battery powered with no field control wiring at the plate itself (only the receiver, sold separately, is wired to the operator).

Product specifications
Touchless actuator supply (8310-813) 12-24 VAC ±10% or 12-24 VDC +30%/-10%, SELV-compatible power supplies only; power consumption < 1.5W; output is a voltage-free relay (max 60VDC/125VAC, 1A resistive, 30W)
900 MHz receiver input voltage (8310-880) 12-24 VAC/VDC; relay contact rating 1.0A@30VDC, 0.3A@60VDC, 0.5A@125VAC
Wireless transmitter power consumption (900 MHz) 30mA (standard TX) / 40mA (RX) / 22mA (retrofit TX)
Receiver capacity up to 74-75 transmitters per standard receiver; unlimited for 'universal' mode
Low-voltage wiring Not required
ElectricalThis empty actuator mounting box has no electrical connection of its own. Low-voltage wiring is not required for this part: zero cable runs; wire type is not applicable. Wiring for separately installed actuators or sensors remains a separate requirement.
Electrical wiring requiredNo
Conditional connectionsHardwired low-voltage actuator contact circuit to the operator, if a hard-wired actuator is mounted in the box: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints 8310-856 series hard-wired actuator to Operator control input; when Installation configuration is Optional accessory selected: IF a hard-wired 4-1/2" round actuator (e.g. 8310-856) is selected and mounted in this box. Actuators provide normally open dry contacts. Cable run count, conductor count and cable spec are not documented for this box.

Official manufacturer documents