Camden CX-DE1220-B1 – Delayed egress mag lock, double door, 15s fixed, BOCA

Delayed egress mag lock, double door, 15s fixed, BOCA compliant Variant record generated from manufacturer nomenclature (https://www.camdencontrols.com/products/DE1200); price inherited from product #3450 pending owner confirmation.

SKU: CX-DE1220-B1
Category: , ,
Brands:

Description

Delayed egress mag lock, double door, 15s fixed, BOCA compliant Variant record generated from manufacturer nomenclature (https://www.camdencontrols.com/products/DE1200); price inherited from product #3450 pending owner confirmation.

Reviews

There are no reviews yet.

Be the first to review “Camden CX-DE1220-B1 – Delayed egress mag lock, double door, 15s fixed, BOCA”

Your email address will not be published. Required fields are marked *

Product specifications
Low-voltage wiring Required
BasisStructured, independently qualified product connection evidence
PreparationFor indoor double leaves swinging outward in the same direction, place main CX-DE1200 on the right and tandem CX-DE1201 on the left when viewed from inside. Drill mounting and 1/2-inch cable-access holes to the supplied template, mount frame plates and door armature housings, and route cable through the frame to both locks.
ElectricalProvide auto-sensing 12/24 VDC +/-10% from a UL 294 or UL 603 listed Class 2 power-limited supply. Observe input polarity and keep field wiring within 30m (98.5ft). Use the exact double-door wiring diagram for the main/tandem interlock and separate supply circuits; a fire alarm condition releases both doors immediately.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsScoped installation connections for CX-DE1220-B1: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating Use the selected manufacturer configuration. Numeric field counts and cable-run quantities remain unknown unless separately stated.; endpoints CX-DE1220-B1 documented terminals or leads to Selected external power and control circuits; when Installation configuration is The exact double-door manual requires four interconnection conductors between main and tandem: Lock +/- pair and Ex-Trig NO/C pair as depicted. Tandem PWR +/- is a separately depicted power-supply circuit, not part of that four-conductor interlock. Optional speaker, keypad, key switch and monitoring require their own selected circuits. Remove J10 only when the NC dry fire/smoke contact is connected to Fire P. Four is the main-to-tandem interlock count, not a whole-system field-conductor total.; Main-to-tandem lock interconnection: cable runs quantity unspecified; 4 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Main/tandem interconnection only; no universal cable-run or new cable-pull count.; endpoints Main CX-DE1200 Lock +/- and Ex-Trig NO/C to Tandem CX-DE1201 matching interconnect terminals; when Installation configuration is Four conductors only BETWEEN the main and tandem locks: the Lock +/- pair and Ex-Trig NO/C pair shown in the exact double-door manual. Tandem supply power is separate. This is not a whole-system total, count of internal device tails, or cable-run quantity. Select optional controls and monitoring separately.