600lb surface mount double door mag lock, basic Variant record generated from manufacturer nomenclature (https://www.camdencontrols.com/products/CX_92_S); price inherited from product #3402 pending owner confirmation.
600lb surface mount double door mag lock, basic Variant record generated from manufacturer nomenclature (https://www.camdencontrols.com/products/CX_92_S); price inherited from product #3402 pending owner confirmation.
600lb surface mount double door mag lock, basic Variant record generated from manufacturer nomenclature (https://www.camdencontrols.com/products/CX_92_S); price inherited from product #3402 pending owner confirmation.
| Low-voltage wiring | Required |
|---|---|
| Basis | Structured, independently qualified product connection evidence |
| Preparation | Use the supplied sticker template to prepare the armature-plate holes. Attach the armature hardware, close the door and mark the frame to align the electromagnet. Attach the mounting plate with the supplied fasteners, route the wires through it and secure the magnet and anti-tamper hardware. Install indoors in a dry location and place the power supply inside a secured or protected area. Choose the exact manufacturer bracket/template for the actual swing and door material. |
| Electrical | Requires a 12 or 24 VDC external low-voltage supply. Set the input jumpers before power-on. The PCB diagram shows a two-conductor positive/negative external input at each lock module; the coil-output connector is separate from that field input. This double lock uses a parallel power arrangement for its modules. The manual does not specify field cable gauge or cable-jacket/run quantities. It also mentions connecting a magnetic-contact wire to the monitoring system without establishing its field cable topology; keep that connection separate and unresolved. No physical cable-jacket/run count is inferred from terminal or conductor counts. |
| Preparation required | Yes |
| Electrical wiring required | Yes |
| Conditional connections | Basic double-lock power interface per module: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field-wire gauge, material, shielding and physical cable-jacket/run quantity are not stated in this manual.; endpoints External12/24VDC power supply to Individual lock module + and – input terminals; when Installation configuration is Exact CX-92S-06 basic model only, with the jumpers matched to the selected12VDC or24VDC supply. Per module in the original double-lock parallel-power arrangement; this is not a total conductor count for both doors. Physical cable jackets/runs are not specified; monitoring or other options are not included.; Magnetic-contact connection mentioned by the basic double-lock instructions: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating Unknown field topology,wire type and cable quantity; obtain manufacturer/system clarification.; endpoints Manufacturer-mentioned magnetic contact wire to Selected door monitoring system; when Installation configuration is The exact basic-model manual instructs a magnetic-contact connection, but its PCB drawing supplies no field topology or cable specification for that interface. Establish the actually supplied contact and monitoring configuration before assigning field conductors or runs. |