Description
Series: CX-WC Series
Type: Barrier Free Restroom Control
Column™ Switch Restroom Control Kits
Brand: Camden
Manufacturer Part Number: CX-WC18SLVR
Source: Camden Controls product page
Column™ Switch Restroom Control Kits
Series: CX-WC Series
Type: Barrier Free Restroom Control
Column™ Switch Restroom Control Kits
Brand: Camden
Manufacturer Part Number: CX-WC18SLVR
Source: Camden Controls product page
| mount | flush, surface |
|---|
| Low-voltage wiring | Connection count needs review |
|---|---|
| Preparation | Use the exact delivered side-load column mounting template and sensor instructions to set the wall positions and cable entry. Select the outside open, inside open and privacy lock locations. Test contact activation, inside release, outside lockout, door-contact reset and LED indications. Set the hands-free sensors to external colour control when driven by the controller and confirm their detection range and activation time. |
| Electrical | The reviewed normally-unlocked arrangement uses the CX-33 power input and separate strike supply. DRY1 receives the outside open contact, DRY2 the inside open contact, DRY3 the lock contact, and DRY4 the normally-closed door contact. Relay2 drives the operator activation loop; relay1 switches the strike circuit. Each selected input or operator loop uses two external low-voltage conductors. Each hands-free sensor has red/black power and a green-NO/blue-COM contact circuit. Green and blue connect to the local column-switch black leads as shown. Purple NC is an alternative factory lead. External LED control uses yellow for green and white for red/blue, with the shared black return; that shared return is already part of sensor power and must not be counted twice when selecting cable. The default open mode pins give internal colour control; the diagram requires shorted pins for external colour control. These are circuit conductors, not physical cable-run quantities. Select mode-specific strike fail behavior, sensor/LED configuration, cable size and routing for the installation. |
| Conditional connections | CX-WC18SLVR controller power: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Select field cable size, grouping/routes and run quantities; shared return counts are not additive.; endpoints External matched supply to CX33 power pair; when Installation configuration is Selected base diagram; LED circuit only for equipped columns. Sensor LED common shares power return. Match actual mode and delivered device revision.; CX-WC18SLVR outside open: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Select field cable size, grouping/routes and run quantities; shared return counts are not additive.; endpoints Outside column contact to CX33 DRY1; when Installation configuration is Selected base diagram; LED circuit only for equipped columns. Sensor LED common shares power return. Match actual mode and delivered device revision.; CX-WC18SLVR inside open: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Select field cable size, grouping/routes and run quantities; shared return counts are not additive.; endpoints Inside column contact to CX33 DRY2; when Installation configuration is Selected base diagram; LED circuit only for equipped columns. Sensor LED common shares power return. Match actual mode and delivered device revision.; CX-WC18SLVR privacy lock: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Select field cable size, grouping/routes and run quantities; shared return counts are not additive.; endpoints Lock column contact to CX33 DRY3; when Installation configuration is Selected base diagram; LED circuit only for equipped columns. Sensor LED common shares power return. Match actual mode and delivered device revision.; CX-WC18SLVR door contact: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Select field cable size, grouping/routes and run quantities; shared return counts are not additive.; endpoints Normally-closed door contact to CX33 DRY4; when Installation configuration is Selected base diagram; LED circuit only for equipped columns. Sensor LED common shares power return. Match actual mode and delivered device revision.; CX-WC18SLVR operator activation: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Select field cable size, grouping/routes and run quantities; shared return counts are not additive.; endpoints CX33 relay2 contact pair to Operator activation input; when Installation configuration is Selected base diagram; LED circuit only for equipped columns. Sensor LED common shares power return. Match actual mode and delivered device revision.; CX-WC18SLVR LED indication: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Select field cable size, grouping/routes and run quantities; shared return counts are not additive.; endpoints Yellow/white controls and shared black power return to Each equipped column LED circuit; when Installation configuration is Selected base diagram; LED circuit only for equipped columns. Sensor LED common shares power return. Match actual mode and delivered device revision.; CX-WC18SLVR sensor power: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Select field cable size, grouping/routes and run quantities; shared return counts are not additive.; endpoints Matched sensor DC supply to Each sensor red/black power leads; when Installation configuration is Selected base diagram; LED circuit only for equipped columns. Sensor LED common shares power return. Match actual mode and delivered device revision. |