HES 8300 Series

$50.00

The fire-rated, concealed solution for cylindrical locksets.

SKU: HES-8300-SERIES
Category:
Brands:

Description

The fire-rated, concealed solution for cylindrical locksets.

Brand: HES

Category: Electric Strikes

List Price Range: $647 – $811

Source: HES product page

Additional information

finish

605, 606, 612, 629, 630

Reviews

There are no reviews yet.

Be the first to review “HES 8300 Series”

Your email address will not be published. Required fields are marked *

The HES 8300 Series is a compact, high-performance electric strike featuring a unique concealed design for use with cylindrical locksets, complying with guidelines for retrofit into fire-rated frames and requiring no cutting on the frame for a 4-7/8" ANSI prep.

Product specifications
Voltage 12/24
Static Strength (lbs) 1,500
Dynamic Strength (ft-lbs) 70
Endurance (cycles) 1,000,000
Fail Safe | Fail Secure Field selectable fail safe/fail secure
Monitoring Installation Factory Configured
Monitoring Options Latchbolt Monitoring
Lock Type Cylindrical Lock
Adjustability Vertical
Surface Mounting No Cutting Required
Frame Material Metal|Wood|Aluminum
Latchbolt Accommodation Up to 5/8" (1/2"-5/8" cylindrical latchbolt, 5/8" with 1/8" door gap)
Strike Body Depth (in) 1.0625
Strike Body Height (in) 4.875
Included in Box 8000 | 8300 Electric Strike Body, Sticky Shims (optional use), 12 & 24 Volt Plug In Connectors
Low-voltage wiring Connection count needs review
PreparationThe jamb must be prepared for the lockset using the appropriate cutout template. The strike may fit an existing ANSI A115.2 1" deep dustbox without cutting. If it is placed in an existing dustbox, a hole must be drilled for the wire connections. Before installation, the correct 12 VDC or 24 VDC plug-in connector must be selected to match system power. The faceplate must also be chosen, and the strike must be set to Fail Secure or Fail Safe mode.
ElectricalSolenoid operation is 12 VDC or 24 VDC for continuous duty. AC operation is 12 VAC, 16 VAC or 24 VAC only for intermittent duty, with 10% maximum duty cycle and 2 minutes maximum on-time. Select the voltage-labelled connector for the actual system voltage and verify the input with a multimeter before connection. Optional monitoring contacts are separate from strike power.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsSolenoid power pair, illustrated fail-secure circuit: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Match the strike voltage-labelled connector to the selected 12 or 24 VDC system; use the model-specific manufacturer gauge table. Nonnumeric same-interface installation context (does not broaden the count condition): Use the actual manufacturer voltage and operating-mode configuration. The power connection is separate from optional monitoring. Internal coil links, pigtail lead count and controller contacts do not establish one total field conductor count or cable-run quantity. Use the manufacturer supply/duty specification for the exact model; actual cable length and gauge are installation-specific.; endpoints 8300 strike power connector to External DC power source and control relay NO contact; when Installation configuration is For the 12 or 24 VDC fail-secure connection shown in Diagram 1a: two field conductors terminate at the strike power interface, one positive through the external control relay NO contact and one negative/common return. This excludes internal coil-configuration links, optional monitoring conductors and protective earth. It does not establish cable-run quantities or a universal conductor total for other configurations.

Official manufacturer documents