Description
The Grade 1, fire-rated, low-profile solution for cylindrical locksets.
Brand: HES
Category: Electric Strikes
List Price Range: $435 – $555
Source: HES product page
The Grade 1, fire-rated, low-profile solution for cylindrical locksets.
Brand: HES
Category: Electric Strikes
List Price Range: $435 – $555
Source: HES product page
| finish | 605, 606, 612, 629, 630 |
|---|
The HES 5300 Series is a compact, high-performance electric strike designed for fire-rated openings with cylindrical locksets where there is limited space behind the jamb.
| Voltage | 12/24 |
|---|---|
| Static Strength (lbs) | 1,500 |
| Dynamic Strength (ft-lbs) | 70 |
| Endurance (cycles) | 500,000 |
| Fail Safe | Fail Secure | Field selectable fail safe/fail secure |
| Grade | Grade 1 |
| Monitoring Installation | Factory Configured |
| Monitoring Options | Latchbolt Monitoring |
| Lock Type | Cylindrical Lock |
| Adjustability | None |
| Frame Material | Metal|Wood |
| Latchbolt Accommodation | Up to 5/8" (1/2"-5/8", 5/8" with 1/8" door gap) |
| Strike Body Depth (in) | 1.0625 |
| Strike Body Height (in) | 4.875 |
| Fire Rating – Single Door | 3 hour (Fail Secure Only) |
| Included in Box | 5000 | 5300 Electric Strike Body, Trim Enhancer & Screws (#4-40 x 1/8"), 12 & 24 Volt Plug In Connectors |
| Low-voltage wiring | Required |
| Basis | Structured, independently qualified product connection evidence |
| Preparation | The frame must be cut and prepared for the lockset using the appropriate cutout template before the strike is installed. The faceplate (501, 501A, 502, 503 or 504 option) is chosen and fitted to the strike. The strike ships in Fail Secure mode, and converting it to Fail Safe is an optional on-site step. Fail Safe conversion negates the fire rating on the 5300. The correct plug-in connector (12 VDC or 24 VDC) is selected to match the system power. |
| Electrical | Solenoid operation is 12 VDC or 24 VDC for continuous duty. AC operation is 12 VAC, 16 VAC or 24 VAC only for intermittent duty, with 10% maximum duty cycle and 2 minutes maximum on-time. Select the voltage-labelled connector for the actual system voltage and verify the input with a multimeter before connection. Optional monitoring contacts are separate from strike power. |
| Preparation required | Yes |
| Electrical wiring required | Yes |
| Conditional connections | Control relay switching the strike supply (Fail Secure example, Diagram 3a): cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints Power supply positive to Control relay C and NO (by others) to Strike supply lead (VIO 24V / RED 12V); when Installation configuration is Base product, Fail Secure wiring example labelled 5000/5300: the control relay is supplied by others and switches the power to the strike. Cable count and boundary are not documented.; Solenoid power pair, illustrated fail-secure circuit: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Match the strike voltage-labelled connector to the selected 12 or 24 VDC system; use the model-specific manufacturer gauge table. Nonnumeric same-interface installation context (does not broaden the count condition): Use the actual manufacturer voltage and operating-mode configuration. The power connection is separate from optional monitoring. Internal coil links, pigtail lead count and controller contacts do not establish one total field conductor count or cable-run quantity. Use the manufacturer supply/duty specification for the exact model; actual cable length and gauge are installation-specific.; endpoints 5300 strike power connector to External DC power source and control relay NO contact; when Installation configuration is For the 12 or 24 VDC fail-secure connection shown in Diagram 3a: two field conductors terminate at the strike power interface, one positive through the external control relay NO contact and one negative/common return. This excludes internal coil-configuration links, optional monitoring conductors and protective earth. It does not establish cable-run quantities or a universal conductor total for other configurations. |