Camden CX-ED1799L – Dual monitor strike body with (2) monitor switches

$50.00

Dual monitor strike body with (2) monitor switches

SKU: CX-ED1799L
Category:
Brands:

Description

Series: CX-ED1689L-4 & CX-ED1799L-8

Type: 'Universal' Low Profile & Dual Monitor Grade 1 Electric Strikes

Configuration: Strike Body Only

Dual monitor strike body with (2) monitor switches

Brand: Camden

Manufacturer Part Number: CX-ED1799L

Source: Camden Controls product page

Reviews

There are no reviews yet.

Be the first to review “Camden CX-ED1799L – Dual monitor strike body with (2) monitor switches”

Your email address will not be published. Required fields are marked *

Camden CX-ED1689L and CX-ED1799L are all-in-one electric locks with Grade 1 fire rating for use with all mortise and cylindrical locksets. Both models include latch monitoring and come with 4 or 8 faceplates, offering universal performance with field-selectable voltage and fail-safe/fail-secure operation.

Product specifications
Voltage 12/24 VAC/VDC
Current draw 300 mA @ 12V AC/DC, 150 mA @ 24V AC/DC
Static strength 1,500 lbs (680 kg)
Dynamic strength 70 ft-lbs (94.92 Nm)
Endurance 1,500,000 cycles (factory tested)
UL verified cycles 250,000 cycles (UL verified)
Mode field selectable fail-safe/fail-secure
Operation AC buzz, DC silent
Duty continuous
Lock monitor switch rating 2 x SPST, 100mA @ 24V DC, resistive
Latch monitor switch rating SPDT, 100mA @ 24V DC, resistive
Dimensions (CX-ED1689L-4) 4-7/8"H x 1-5/8"W x 1-3/8"D (124mm x 41mm x 36mm)
Dimensions (CX-ED1799L-8) 4-7/8"H x 1-5/8"W x 1-21/32"D (124mm x 41mm x 42mm)
CX-ED1689L-4 faceplate kit latch monitor lock with (4) latch faceplates: CX-EMP100, CX-EMP200, CX-EMP300, CX-EMP400
CX-ED1799L-8 faceplate kit dual monitor lock with (8) latch/deadbolt faceplate package: CX-EMP100, CX-EMP200, CX-EMP300, CX-EMP400, CX-EMP110, CX-EMP210, CX-EMP310, CX-EMP410
Faceplate finish stainless steel; black architectural finish (BHMA 622, US19) also available
Low-voltage wiring Connection count needs review
PreparationThis body-only listing requires a separately selected faceplate. Check the existing jamb cutout against the actual strike/faceplate template, mount with the specified machine screws and test-fit before final tightening. Position the bolt-monitor assembly for the actual handing. Adjust the keeper gap with the supplied shims and securely retighten the retaining screws. Fit the deadbolt bracket only as required by the selected lockset, engaging its key in the strike slot before fastening. Confirm the permitted fire-rated configuration with the manufacturer before relying on a rating: the installation manual says fail-secure only, while the2026 addendum labels fail-safe. This conflict is unresolved.
ElectricalSelect the actual12/24V AC/DC supply and voltage harness. For the illustrated DC cut-wire option,12V joins red/black positive and blue/green negative;24V uses red positive and green negative with black/blue joined locally. Use two external supply conductors and fit the supplied varistor across the pair; factory coil tails are separate. The specifications give300mA at12V AC/DC and150mA at24V AC/DC. Follow the documented Class2 power-limited supply requirement. Two independent latch/deadbolt monitor pairs use white COM and purple NO, two conductors per selected external monitoring circuit. Identify the actual mechanical channel before termination. The separate strike monitor uses purple COM, yellow NO and blue NC; select one throw or both (two or three conductors). Monitor contact ratings are100mA at24V DC, separate from strike operating power. The door-position contact may be monitored separately or in series with a bolt monitor. Choose the actual monitoring layout, field cable type/gauge/shielding and physical routes; do not add alternative connections or treat factory leads as cable runs.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsOptional SPDT Form C latch bolt monitor connection: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints optional Form C latch bolt monitor (60-35E008) to monitoring system; when Installation configuration is Optional accessory selected: IF the optional Form C latch bolt monitor is ordered. Its White/Yellow and White/Brown wire pairs give the NC/NO options. Not part of the base strike.; CX-ED1799L selected voltage-harness power: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Cable type, gauge, shielding and physical routes unspecified; local joins and factory leads separate.; endpoints Compatible external12/24VAC/DC supply to Matching strike voltage harness; when Installation configuration is Select harness for actual voltage and operating mode; external supply pair distinct from internal coil leads.; CX-ED1799L 12VDC cut-wire alternative: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Cable type, gauge, shielding and physical routes unspecified; local joins and factory leads separate.; endpoints Compatible external 12VDC supply to Red/black positive, blue/green negative; when Installation configuration is Only when this documented DC cut-wire configuration is used instead of the harness; local join and varistor are not cable runs.; CX-ED1799L 24VDC cut-wire alternative: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Cable type, gauge, shielding and physical routes unspecified; local joins and factory leads separate.; endpoints Compatible external 24VDC supply to Red positive, green negative; black/blue joined locally; when Installation configuration is Only when this documented DC cut-wire configuration is used instead of the harness; local join and varistor are not cable runs.; CX-ED1799L selected latch monitor: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Cable type, gauge, shielding and physical routes unspecified; local joins and factory leads separate.; endpoints External low-voltage monitoring input to Verified latch channel white COM and purple NO; when Installation configuration is Only if this monitor is used; identify the actual mechanical channel and verify closure when its bolt engages. Separate from strike power and FormC monitor.; CX-ED1799L selected deadbolt monitor: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Cable type, gauge, shielding and physical routes unspecified; local joins and factory leads separate.; endpoints External low-voltage monitoring input to Verified deadbolt channel white COM and purple NO; when Installation configuration is Only if this monitor is used; identify the actual mechanical channel and verify closure when its bolt engages. Separate from strike power and FormC monitor.; CX-ED1799L selected strike monitor NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Cable type, gauge, shielding and physical routes unspecified; local joins and factory leads separate.; endpoints External low-voltage monitoring input to Purple COM and yellow NO; when Installation configuration is When the separate FormC strike monitor is present and used with NO; activation changes contact state. Alternatives are not additive.; CX-ED1799L selected strike monitor NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Cable type, gauge, shielding and physical routes unspecified; local joins and factory leads separate.; endpoints External low-voltage monitoring input to Purple COM and blue NC; when Installation configuration is When the separate FormC strike monitor is present and used with NC; activation changes contact state. Alternatives are not additive.; CX-ED1799L selected strike monitor NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Cable type, gauge, shielding and physical routes unspecified; local joins and factory leads separate.; endpoints External low-voltage monitoring input to Purple COM, yellow NO and blue NC; when Installation configuration is When the separate FormC strike monitor is present and used with NO and NC; activation changes contact state. Alternatives are not additive.; CX-ED1799L separate door contact: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Cable type, gauge, shielding and physical routes unspecified; local joins and factory leads separate.; endpoints External low-voltage monitoring input to Concealed door-position contact; when Installation configuration is Only when monitored separately; contact open with door open and closed with door shut.; CX-ED1799L series door and bolt monitoring: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating Cable type, gauge, shielding and physical routes unspecified; local joins and factory leads separate.; endpoints Selected external monitoring input to Door contact and selected bolt-monitor series arrangement; when Installation configuration is Alternative series wiring: actual route and local interconnections must be specified; no aggregate count is established by the separate circuit pairs.

Official manufacturer documents