Camden CX-DA400 – Door alarm, with relays, timers, reset key, double gang, 12/24V AC/DC

$75.00

Door alarm, with relays, timers, reset key, double gang, 12/24V AC/DC

SKU: CX-DA400
Category:
Brands:

Description

Series: CX-DA400 Series

Type: Line Powered Door Monitor Alarm

Door alarm, with relays, timers, reset key, double gang, 12/24V AC/DC

Brand: Camden

Manufacturer Part Number: CX-DA400

Source: Camden Controls product page

Reviews

There are no reviews yet.

Be the first to review “Camden CX-DA400 – Door alarm, with relays, timers, reset key, double gang, 12/24V AC/DC”

Your email address will not be published. Required fields are marked *

CX-DA-400 double gang door monitor alarm features a rugged stainless steel faceplate, 4 inputs, 5 outputs and has a range of adjustable time delay functions. It is designed to complement any access control system by providing prop/door held open and intrusion/door forced open detection, as well as local alarm and reset.

Product specifications
Low-voltage wiring Connection count needs review
PreparationFlush-mount in a double-gang electrical box with the manual-required 2.5-inch depth. Configure the selected door supervision, intrusion detection, valid-user shunt/voltage-sense and alarm timing options before commissioning. Leave the reserved diagnostic jumper OFF. The DA401-only tamper-switch procedure is not assigned to the DA400. Test valid access, door-held alarm, forced-door alarm and reset/bypass behavior for the selected configuration.
ElectricalPower input is 12 to 24 VAC/DC at TS1 terminals 11/12, non-polarized. The NC door contact uses TS1 7/8. Optional dry-contact shunt uses TS1 1/2, voltage sense uses TS1 3 negative and 4 positive, remote LED uses TS1 5/6, and NO remote reset/bypass uses TS1 9/10. Set the input jumpers for the selected interface. Optional TS2 output groups are bypass/key status COM13 NO14 NC15, intrusion/tamper COM16 NO17 NC18, door-prop COM19 NO20 NC21, and door status COM22 NO23 NC24. Select COM with NO or NC for each used circuit; these alternatives are not cumulative. Outputs change state on power loss. Each selected external low-voltage circuit uses two conductors; physical runs, shared routing and cable specification remain site decisions. Door supervision requires the specified resistor network at the door contact; confirm the delivered network values and remote LED compatibility before connecting those options.
Preparation requiredYes
Conditional connectionsCX-DA400 power input: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field gauge/type and physical route/run quantities require installation selection.; endpoints External matched supply to TS1 11/12; when Installation configuration is Base power; non-polarized.; CX-DA400 NC door input: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field gauge/type and physical route/run quantities require installation selection.; endpoints External NC door contact to TS1 7/8; when Installation configuration is Select supervised or unsupervised contact circuit; resistor network at door if supervised.; CX-DA400 optional shunt input: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field gauge/type and physical route/run quantities require installation selection.; endpoints External valid-user dry contact to TS1 1/2; when Installation configuration is Only selected shunt input; configure NO/NC jumper.; CX-DA400 optional voltage sense: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field gauge/type and physical route/run quantities require installation selection.; endpoints External lock power sense to TS1 3 negative and 4 positive; when Installation configuration is Only selected voltage-sense input; configure normally energized/de-energized mode.; CX-DA400 optional remote LED: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field gauge/type and physical route/run quantities require installation selection.; endpoints Compatible external indicator to TS1 5/6; when Installation configuration is Only if compatible remote LED is selected; confirm electrical compatibility.; CX-DA400 optional bypass input: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field gauge/type and physical route/run quantities require installation selection.; endpoints External NO reset/bypass contact to TS1 9/10; when Installation configuration is Only if remote reset/bypass is selected.; CX-DA400 optional bypass status NO output: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field gauge/type and physical route/run quantities require installation selection.; endpoints TS2 COM/NO 13/14 to External low-voltage monitor; when Installation configuration is Only selected NO monitoring loop; NC is an alternative, not additional conductors.; CX-DA400 optional intrusion alarm NO output: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field gauge/type and physical route/run quantities require installation selection.; endpoints TS2 COM/NO 16/17 to External low-voltage monitor; when Installation configuration is Only selected NO monitoring loop; NC is an alternative, not additional conductors.; CX-DA400 optional door-prop alarm NO output: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field gauge/type and physical route/run quantities require installation selection.; endpoints TS2 COM/NO 19/20 to External low-voltage monitor; when Installation configuration is Only selected NO monitoring loop; NC is an alternative, not additional conductors.; CX-DA400 optional door status NO output: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field gauge/type and physical route/run quantities require installation selection.; endpoints TS2 COM/NO 22/23 to External low-voltage monitor; when Installation configuration is Only selected NO monitoring loop; NC is an alternative, not additional conductors.

Official manufacturer documents