Description
Series: CM-300/310 Series
Type: Rectangular LED Illuminated Switch
Configuration: Narrow Faceplate
Green button,
Brand: Camden
Manufacturer Part Number: CM-310EE
Source: Camden Controls product page
Series: CM-300/310 Series
Type: Rectangular LED Illuminated Switch
Configuration: Narrow Faceplate
Green button,
Brand: Camden
Manufacturer Part Number: CM-310EE
Source: Camden Controls product page
Camden Door Controls CM-300/310 Series LED Illuminated Exit Switches are economical illuminated exit controls with 1/2" x 3/4" buttons available in red or green, supplied with a stainless steel faceplate in 1 3/4" or 2 3/4" widths. The SPDT momentary switch is UL/CSA approved and the LED bulb runs on 12V or 24V DC. CM-310EE adds an integrated 30-second timer with double-break circuitry for magnetic lock applications.
| Operating voltage | 12 or 24 V DC |
|---|---|
| Time delay | 30 seconds |
| Contact rating | 4 amps @ 30 VDC |
| Switch life | 15,000 hrs. @ rated capacity (bulb life) |
| Mounting | 2 x #6-32 machine screws |
| Dimensions | 2.75" W x 4.5" H x 1 5/16" (70mm x 114mm x 33mm) |
| Low-voltage wiring | Connection count needs review |
| Preparation | The installation description specifies a narrow door-jamb flush mounting arrangement, but the specification table is labelled CM-300 and gives a wider footprint. Verify the delivered CM-310EE faceplate and box before cutting. Connect the supplied prewired leads, tuck wiring into the included retrofit box and fasten the faceplate with the supplied screws. |
| Electrical | Use a 12 or 24 VDC supply for the unit. The timer and LED have separate red/black supply pairs, two external interface conductors for each pair. The illustrated maglock circuit connects white to supply positive, directly or through the selected motion-detector relay, and green to maglock positive: two external conductors at that controlled-loop interface. Maglock negative returns separately to supply negative. These interface counts are not a bundled cable total or physical run count. Keep the LED inline resistor for 24 VDC; for 12 VDC follow the documented removal instruction on the black light lead, preserving the separate timer supply. The fixed delay is 30 seconds, retriggerable; the internal timer and pushbutton are in series in the white/green double-break circuit. Field cable type, gauge, shielding and run quantities are unspecified. Optional motion-detector circuits remain separate. |
| Preparation required | Yes |
| Electrical wiring required | Yes |
| Conditional connections | White lead routed through the relay of a motion detector: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints CM-310EE White lead to Motion detector relay to + voltage source; when Installation configuration is Optional accessory selected: IF an optional motion detector is selected; otherwise White goes to the power supply positive terminal.; White lead routed through optional motion detector relay: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints CM-310EE White lead to Motion detector relay output; when Installation configuration is Optional accessory selected: IF an optional motion detector (request-to-exit sensor) is selected: the White lead goes through the motion detector relay instead of directly to positive. The motion detector's own power connection is a separate accessory circuit.; Selected CM-310EE Timer supply: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified; interface counts do not establish a universal bundled cable count.; endpoints Selected external low-voltage supply to CM-310EE timer red/black pair; when Installation configuration is Selected12/24VDC timer supply branch. Separate from LED supply pair. No physical run quantity inferred.; Selected CM-310EE LED supply: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified; interface counts do not establish a universal bundled cable count.; endpoints Selected external low-voltage supply to CM-310EE LED red/black pair; when Installation configuration is Selected12/24VDC led supply branch. Retain inline LED resistor for24VDC; follow black-light-lead removal instruction for12VDC. No physical run quantity inferred.; Selected CM-310EE Illustrated maglock control loop: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified; interface counts do not establish a universal bundled cable count.; endpoints Selected external low-voltage maglock/supply circuit to CM-310EE white input and green output; when Installation configuration is Illustrated maglock configuration: white to supply positive directly or through selected motion relay; green to lock positive. Lock negative return separate. No physical run quantity inferred. |
Reviews