Camden CX-ED1579L – Grade 1 ‘All In One‘ fire rated strike, 12/24V AC/DC, for mortise and cylindrical locksets, comes with 6 stainless steel faceplates

$50.00

Grade 1 ‘All In One‘ fire rated strike, 12/24V AC/DC, for mortise and cylindrical locksets, comes with 6 stainless steel faceplates

SKU: CX-ED1579L
Category:
Brands:

Description

Series: CX-ED1579L

Type: 'ALL IN ONE' Fire Rated Electric Strike

Grade 1 ‘All In One‘ fire rated strike, 12/24V AC/DC, for mortise and cylindrical locksets, comes with 6 stainless steel faceplates

Brand: Camden

Manufacturer Part Number: CX-ED1579L

Source: Camden Controls product page

Reviews

There are no reviews yet.

Be the first to review “Camden CX-ED1579L – Grade 1 ‘All In One‘ fire rated strike, 12/24V AC/DC, for mortise and cylindrical locksets, comes with 6 stainless steel faceplates”

Your email address will not be published. Required fields are marked *

Camden's CX-ED1579L is an all-in-one, Grade 1 fire-rated electric strike with built-in latch monitoring at no additional cost, for use with mortise and cylindrical locksets. It offers universal performance with five stainless steel faceplates, field-selectable voltage, and fail-safe/fail-secure operation, and carries UL listing with a 3-hour fire rating (UL10C/CAN4-S104).

Product specifications
Voltage 12/24V AC/DC
Current draw 260 mA @ 12V AC/DC / 150 mA @ 24V AC/DC
Static strength 1,500 lbs (683.4 kg)
Dynamic strength 70 ft-lbs (1.36Nm, as stated in source)
Operation AC buzz, DC silent
Duty continuous (DC)
Mounting non-handed
Endurance 1,500,000 cycles (factory tested) / 250,000 cycles (UL verified)
Fire rating UL10C/CAN4-S104, 3 hours (fail-secure mode only)
Latch monitor SPDT, 100mA @ 24VDC
Dimensions 4-7/8"L x 1-1/4"W x 1-3/4"D (124mm x 32mm x 45mm)
Faceplates included 5 stainless steel faceplates (CX-EMP-1 through CX-EMP-5)
Low-voltage wiring Required
BasisStructured, independently qualified product connection evidence
PreparationUse the purchased stainless-steel faceplate set. Select the correct faceplate and template for the actual mortise or cylindrical lockset and frame. Prepare the jamb to the matching drawing, install the brackets loosely, and use spacers as described to make the faceplate flush before final tightening. Place the latch-monitor plate, deadbolt bracket and keeper shims for the actual right- or left-hand installation. Verify latch engagement and preserve exit/panic hardware operation. The manufacturer limits the documented fire rating to fail-secure operation; do not assume that rating for fail-safe mode.
ElectricalSelect the actual12/24V AC/DC supply and matching voltage connection before wiring. At12V use red/black as one supply connection and blue/green as the other; at24V use red and green for the supply with black/blue joined locally. The diagram gives DC positive/negative polarity; do not treat its black/blue dash as a negative supply designation. Each selected supply circuit uses two external conductors, distinct from four factory coil tails. Fit the supplied varistor across the supply pair as shown. The manual specifies260mA at12V AC/DC and150mA at24V AC/DC. The manufacturer requires the documented Class2 power-limited supply for its listed application. Latch monitoring is separate: yellow COM, purple NO and brown NC; use two conductors for one selected throw or three for both. Its contact rating is100mA at24V DC, separate from operating power. Verify monitor state with the actual latch. Select fail mode and equipment before specifying cable type, gauge, shielding and physical routes; terminal and factory-tail counts do not determine cable-run quantities.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsCX-ED1579L selected operating supply: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical cable-run quantities unspecified; factory tails and local joins separate.; endpoints Compatible selected12/24VAC/DC external supply to Strike power leads configured for selected12V or24V; when Installation configuration is Select the actual voltage and configure the supply leads accordingly; the two external circuit conductors are distinct from four internal coil tails. AC/DC choice follows supplied product rating.; CX-ED1579L 12VDC power alternative: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical cable-run quantities unspecified; factory tails and local joins separate.; endpoints Compatible external 12VDC supply to Red/black positive and blue/green negative; when Installation configuration is Only when the documented 12VDC configuration is selected; varistor across supply, local coil joins separate. Alternatives are not additive.; CX-ED1579L 24VDC power alternative: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical cable-run quantities unspecified; factory tails and local joins separate.; endpoints Compatible external 24VDC supply to Red positive and green negative; black/blue local join; when Installation configuration is Only when the documented 24VDC configuration is selected; varistor across supply, local coil joins separate. Alternatives are not additive.; CX-ED1579L latch monitor COM with NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical cable-run quantities unspecified; factory tails and local joins separate.; endpoints Selected external low-voltage monitoring input to Yellow COM and purple NO; when Installation configuration is Only when this L variant uses NO monitoring; verify latch state. Alternatives are not additive and are separate from operating power.; CX-ED1579L latch monitor COM with NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical cable-run quantities unspecified; factory tails and local joins separate.; endpoints Selected external low-voltage monitoring input to Yellow COM and brown NC; when Installation configuration is Only when this L variant uses NC monitoring; verify latch state. Alternatives are not additive and are separate from operating power.; CX-ED1579L latch monitor COM with NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical cable-run quantities unspecified; factory tails and local joins separate.; endpoints Selected external low-voltage monitoring input to Yellow COM, purple NO and brown NC; when Installation configuration is Only when this L variant uses NO and NC monitoring; verify latch state. Alternatives are not additive and are separate from operating power.

Official manufacturer documents