Camden CM-1000/35 – SPST maintained contact (on/off) switch, 6 A @ 125 VAC, 3 A @ 30 VDC

$25.00

SPST maintained contact (on/off) switch, 6 A @ 125 VAC, 3 A @ 30 VDC

SKU: CM-1000/35
Category:
Brands:

Description

Series: Parts for Key Switches

Configuration: Contact Switches

SPST maintained contact (on/off) switch, 6 A @ 125 VAC, 3 A @ 30 VDC

Brand: Camden

Manufacturer Part Number: CM-1000/35

Source: Camden Controls product page

Reviews

There are no reviews yet.

Be the first to review “Camden CM-1000/35 – SPST maintained contact (on/off) switch, 6 A @ 125 VAC, 3 A @ 30 VDC”

Your email address will not be published. Required fields are marked *

Product specifications
Low-voltage wiring Connection count needs review
PreparationThis is a SPST maintained replacement contact component. When fitting it to a compatible CM-1000 assembly, select the intended left/right switch position behind the faceplate. Fit the octagonal spacer nut on the switch stem, insert the switch from below and secure with the threaded washer. Adjust the switch and spacer height so the cylinder cam presses centrally, operates the contact fully and permits proper reset; test alternating on/off action. Confirm the actual host model, replacement mechanism and cam travel before fitting. Other host assemblies require their own matching instructions.
ElectricalThe purchased component is SPST maintained on/off, with a low-voltage contact rating of 3A at30VDC. This rating is a switching limit, not a required power supply. The SPST contact has two black leads; verify the normal open/closed state of the exact purchased component. In a direct-wired low-voltage control installation, use two field conductors per used pole for common and one throw, or three per used changeover pole for both throws. These are conditional circuit connections; internal wiring to a host device or local transmitter does not itself establish a field cable. The host manual describes18AWG soldered factory leads, which is not a field-cable gauge prescription for this replacement. Parent LED supply requirements do not apply to this contact part. Select cable type, gauge, shielding and physical routes from the connected equipment and installation.
Conditional connectionsCM-1000/35 pole 1 on/off direct-wired control: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical routes unspecified; factory leads distinct.; endpoints Selected external low-voltage controller input to Contact pole 1 two SPST leads; when Installation configuration is Only if this pole is directly wired to the external low-voltage control circuit; maintained action. Use exact on/off contact state. Local host/transmitter wiring is separate; no cable-run quantity inferred.

Official manufacturer documents