Description
Series: CM-1200 & CM-2200 Series
Type: Stainless Steel, Flush mount
Configuration: Single Gang Faceplate
Key Switch, (2) SPDT Momentary
Brand: Camden
Manufacturer Part Number: CM-1250
Source: Camden Controls product page
Series: CM-1200 & CM-2200 Series
Type: Stainless Steel, Flush mount
Configuration: Single Gang Faceplate
Key Switch, (2) SPDT Momentary
Brand: Camden
Manufacturer Part Number: CM-1250
Source: Camden Controls product page
Camden Door Controls CM-1200 and CM-2200 Series flush mount key switches meet the demands of key switch controls, designed for use with standard 1", 1-1/8", or 1-1/4" mortise cylinders. CM-1200 is single gang (2-3/4" wide) and CM-2200 is narrow style (1-3/4" wide); both accept one or two switches and control overhead doors, electric locks, electro-magnetic locks, electric strikes, and motors.
| Faceplate | heavy duty stainless steel |
|---|---|
| Input voltage | 12-24V AC/DC |
| Contact rating standard | 6 A @ 30VDC |
| Contact rating optional | 15 A @ 30VDC |
| Lead wire | 18 AWG color coded soldered leads |
| Mortise cylinder size | 1", 1-1/8", or 1-1/4" |
| Width (CM-1200) | 2-3/4" (70mm) |
| Width (CM-2200) | 1-3/4" (44mm) |
| Included hardware | brass cylinder lock ring, 2 socket/slotted screws, 2 tamperproof screws with driver |
| Low-voltage wiring | Required |
| Basis | Structured, independently qualified product connection evidence |
| Preparation | Fit the aluminum bracket against the stud behind the faceplate. Insert the separately purchased mortise cylinder from the front and align its side grooves with the bracket retainers. If irregular grooves prevent fitting, file the retainers slightly; never remove them completely. Tighten the brass cylinder lock ring to secure the bracket. Fit the supplied switch in the selected bracket hole with its spacer ring and threaded washer. Align the cam centrally over the switch and check key operation before fastening the unit to the selected switch box, wall or receptacle box with the supplied screws. Select the mounting arrangement and compatible cylinder for the installation. |
| Electrical | Base configuration: Key Switch, (2) SPDT Momentary. For each used changeover pole, common plus NO or common plus NC requires two external conductors; common plus both NO and NC requires three. Apply that choice separately to each of the two supplied switches. Do not join independent commons by assumption. These are low-voltage circuit conductor counts, not physical cable-run counts. The supplied 18 AWG soldered leads do not specify field cable gauge. Common is grey; momentary NO is blue and NC orange. The maintained-contact chart lists both throw leads orange, so identify the actual terminal function before connecting. Cable type, gauge, shielding and physical run quantities depend on the selected controller/device and site routing. Optional LED circuits remain separate and require their selected DC option instructions. The standard-contact parts table and family specification give different contact ratings; verify the fitted switch rating. Contact ratings are not supply requirements. |
| Preparation required | Yes |
| Electrical wiring required | Yes |
| Conditional connections | Optional LED indicator circuit (12 V or 24 V DC): cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints LED red (+) and black (-) leads to DC supply (12 VDC or 24 VDC depending on LED option); when Installation configuration is Optional accessory selected: IF an LED indicator option (-7xxx suffix) is selected. Single-colour LEDs use red (+) and black (-) leads; the 560 ohm resistor is integrated for 12 V and a 1.5 k ohm resistor is shown for 24 V. Bi-colour LEDs are 3-wire and are wired through the SPDT switch. LEDs are DC only. Separate from the base switch contact wiring.; Selected base switch 1: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1250 switch 1 common and NO; when Installation configuration is For switch 1, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1250 switch 1 common and NC; when Installation configuration is For switch 1, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1250 switch 1 common, NO and NC; when Installation configuration is For switch 1, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1250 switch 2 common and NO; when Installation configuration is For switch 2, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1250 switch 2 common and NC; when Installation configuration is For switch 2, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-1250 switch 2 common, NO and NC; when Installation configuration is For switch 2, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred. |