Camden CM-2082 – Key Switch, (2) DPDT Momentary

$75.00

Key Switch, (2) DPDT Momentary

SKU: CM-2082
Category:
Brands:

Description

Series: CM-1100 & CM-2000 Series

Type: Cast Aluminum, Flush Mount

Configuration: Narrow Faceplate

Key Switch, (2) DPDT Momentary

Brand: Camden

Manufacturer Part Number: CM-2082

Source: Camden Controls product page

Reviews

There are no reviews yet.

Be the first to review “Camden CM-2082 – Key Switch, (2) DPDT Momentary”

Your email address will not be published. Required fields are marked *

Camden Door Controls, CM-1100 and CM-2000 Series flush mount key switches meet the stringent demands of key switch controls. They are designed for use with standard 1”, 1 1/8”, or 1 1/4” mortise cylinders. Fabricated from 1/4” thick aluminum, into a one piece die cast construction, with unique Camden Manufacturing features.

Product specifications
Low-voltage wiring Required
BasisStructured, independently qualified product connection evidence
PreparationThe CM-2000 series is a mullion-style flush-mount key switch. It accepts a standard mortise cylinder (1" to 1-1/4"), and the cylinder is sold separately in the listed options. A compatible mounting box is listed for the CM-2000 series (CM-23D surface box). Cylinder choice and mounting method are job decisions.
ElectricalBase configuration: Key Switch, (2) DPDT Momentary. For each used changeover pole, common plus NO or common plus NC requires two external conductors; common plus both NO and NC requires three. Each DPDT switch contains two independent poles. Apply that choice separately to each of the two supplied switches. Do not join independent commons by assumption. These are low-voltage circuit conductor counts, not physical cable-run counts. The supplied 18 AWG soldered leads do not specify field cable gauge. Common is grey; momentary NO is blue and NC orange. The maintained-contact chart lists both throw leads orange, so identify the actual terminal function before connecting. Cable type, gauge, shielding and physical run quantities depend on the selected controller/device and site routing. Optional LED circuits remain separate and require their selected DC option instructions. The standard-contact parts table and family specification give different contact ratings; verify the fitted switch rating. Contact ratings are not supply requirements.
Preparation requiredYes
Electrical wiring requiredYes
Conditional connectionsOptional LED indicator circuit (DC only): cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints LED leads to 12 VDC or 24 VDC supply; when Installation configuration is Optional accessory selected: IF an optional LED is ordered or selected. LEDs are DC only, with a 1.5 k ohm resistor used for 24 VDC. This does not apply to the base product.; Switch contact connections for the two DPDT momentary switches (common, normally open and normally closed leads), connected to the controlled or signalling circuit: cable runs quantity unspecified; conductor count unspecified; wire type not documented; size unspecified; shielding unspecified; rating unspecified; endpoints CM-2082 DPDT momentary switch leads to external controlled/signalling circuit (not specified); when Installation configuration is Internal accessory connection; not field cable: Base product, CM-2082 with 2 DPDT momentary switches. The color-coded soldered switch leads are factory leads: grey (x2) common, blue (x2) normally open, orange (x2) normally closed for each DPDT momentary switch. The manual does not document how the leads are extended to field cable or how many cable runs are needed, so no field cable count or conductor count is given.; Selected base switch 1 pole 1: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-2082 switch 1 pole 1 common and NO; when Installation configuration is For switch 1 pole 1, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1 pole 1: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-2082 switch 1 pole 1 common and NC; when Installation configuration is For switch 1 pole 1, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1 pole 1: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-2082 switch 1 pole 1 common, NO and NC; when Installation configuration is For switch 1 pole 1, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1 pole 2: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-2082 switch 1 pole 2 common and NO; when Installation configuration is For switch 1 pole 2, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1 pole 2: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-2082 switch 1 pole 2 common and NC; when Installation configuration is For switch 1 pole 2, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 1 pole 2: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-2082 switch 1 pole 2 common, NO and NC; when Installation configuration is For switch 1 pole 2, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2 pole 1: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-2082 switch 2 pole 1 common and NO; when Installation configuration is For switch 2 pole 1, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2 pole 1: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-2082 switch 2 pole 1 common and NC; when Installation configuration is For switch 2 pole 1, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2 pole 1: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-2082 switch 2 pole 1 common, NO and NC; when Installation configuration is For switch 2 pole 1, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2 pole 2: common and NO: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-2082 switch 2 pole 2 common and NO; when Installation configuration is For switch 2 pole 2, select common and NO. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2 pole 2: common and NC: cable runs quantity unspecified; 2 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-2082 switch 2 pole 2 common and NC; when Installation configuration is For switch 2 pole 2, select common and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.; Selected base switch 2 pole 2: common, NO and NC: cable runs quantity unspecified; 3 conductor(s); wire type not documented; size unspecified; shielding unspecified; rating Field cable type, gauge, shielding and physical run quantity unspecified. Supplied18AWG solderedleads do not establish field cable gauge.; endpoints Selected low-voltage controlled equipment to CM-2082 switch 2 pole 2 common, NO and NC; when Installation configuration is For switch 2 pole 2, select common, NO and NC. This is an alternative pole configuration; do not add it to the other alternatives for the same pole. Use only the supplied switches/poles needed by the controlled equipment. No physical run count is inferred.