Description

CV-110SPK: Slim Line Proximity Reader and Keypad – Camden Door Controls

Source: https://www.camdencontrols.com/category/access/System_Keypads_Prox_Keypads/products/CV_110_SPK

Resources:
https://www.camdencontrols.com/pipelines/resource/3237_Access_Control_Technical_Guide.pdf
https://www.camdencontrols.com/pipelines/resource/3238_S8QAYUC4NEOBTFUBA51L.pdf
https://www.camdencontrols.com/pipelines/resource/3233_CV_110SPK_Manual_R2.pdf
https://www.camdencontrols.com/pipelines/resource/3234_W1UBWZC0SOZ5FITRVT3P.pdf
https://www.camdencontrols.com/pipelines/resource/3235_CV_110SPK_Manual_R2_FR.pdf
https://www.camdencontrols.com/pipelines/resource/3236_9541GRQJIMFF8PEH7SBQ.pdf
https://www.camdencontrols.com/pipelines/resource/3239_CV_110SPK_Spec_Sheet_R3.pdf
https://www.camdencontrols.com/pipelines/resource/3240_8U20I1V8X3NQTD0IORC7.pdf

Reviews

There are no reviews yet.

Be the first to review “CV-110-SPK – CV-110SPK: Slim Line Proximity Reader and Keypad”

Your email address will not be published. Required fields are marked *

Camden CV-110SPK is a single-door, multifunction stand-alone keypad and 125kHz EM-format prox reader with a Wiegand output for interfacing to an access control system or remote card reader, supporting up to 2,000 users via card, PIN, or card+PIN. It is housed in a fully potted, vandal-proof Zinc Alloy electroplated case rated IP68 for indoor or outdoor use, with lock output short-circuit protection, anti-tamper, and a backlit keypad.

Product specifications
Operating voltage 12VDC
User capacity 2,000
Card type EM Format
Read range 1.25" to 2.4" (3cm to 6cm)
Current draw 60mA
Contact type 1 Form 'C'
Contact rating 3A @ 30VDC
Alarm output 20mA
Weather resistance IP68
Door relay time 0 to 99 seconds
Alarm time 0 to 3 minutes
Wiegand interface 8 bit burst for PIN codes, 26 bit for cards
Temperature -49°F to 140°F (-45°C to 60°C)
Dimensions 6" H x 1 3/4" W x 1" D (152mm x 45mm x 25mm)
Low-voltage wiring Required
Cable typelow-voltage control wire (gauge not stated in text)
Conductor countconfig-dependent (see wiring diagram)
Runs per unit1 home run per unit to controller (field/design dependent)
BasisOPERATING VOLTAGE: 12VDC

Official manufacturer documents